PowerFlex Digital DC Drive User Manual -
Publication 20P-UM001C-EN-P - July 2008
1-28
Installation and Wiring
Control Circuit Input Power
The control circuit must be powered by an external 230V AC or 115V AC
single phase power supply. For frame B and C drives only, a jumper is
required between terminals SA and SB for 115V AC control input power.
For frame B drive SA-SB terminal block location, refer to
Figure 1.26 on
page 1-29
. For frame C drive SA-SB terminal block location, refer to
Figure
1.27 on page 1-30
.
Figure 1.23 Frame A Control Circuit Terminal Block Location
Figure 1.24 Frame B Control Circuit Terminal Block Location
Terminals Description
U2, V2
Single phase AC power for the control circuits
U2
V2
U2
V2