62
Rockwell Automation Publication 2198-RM006A-EN-P - December 2020
Appendix C Specifications
Table 45 - Kinetix 5300 (480V, three-phase) Input Power Specifications
Attribute
2198-C4004-ERS
2198-C4007-ERS
2198-C4015-ERS
2198-C4020-ERS
AC input voltage
342…528V rms, three-phase (480V nom)
AC input frequency
47…63 Hz
Main AC input current (rms)
(1)
1.24 A
2.25 A
4.03 A
5.65 A
Max inrush current (0-pk)
15.5 A
15.5 A
15.5 A
15.5 A
Peak AC input current (rms)
3.59 A
6.29 A
12.18 A
16.10 A
Control power input voltage
(2)
21.6…26.4V DC
24V DC nom
Control power input current
(3)
(non-brake motors)
0.4 A
DC
0.4 A
DC
0.9 A
DC
0.9 A
DC
Continuous output current (rms)
1.6 A
2.9 A
5.2 A
7.3 A
Continuous output current (0-pk)
2.3 A
4.1 A
7.4 A
10.3 A
Peak output current (rms)
(4)
5.3 A
9.3 A
18.0 A
23.8 A
Peak output current (0-pk)
7.5 A
13.2 A
25.5 A
33.7 A
Line loss ride through
20 ms
Continuous output power
0.86 kW
1.55 kW
2.78 kW
3.90 kW
Internal shunt on
775V
Internal shunt off
765V
Internal shunt resistor
100
Ω
100
Ω
60
Ω
60
Ω
Internal shunt power
30 W
30 W
50 W
50 W
Bus undervoltage limit
275V
Bus overvoltage limit
810V
Bus capacitance
165 µF
165 µF
280 µF
330 µF
Capacitive energy absorption
8.13 J
13.79 J
16.26 J
Efficiency
97%
Short-circuit current rating
200,000 A (rms) symmetrical
(1) Drives are limited to one power cycle per minute.
(2) The cooling fan runs as part of the control power startup routine, when the inverter is enabled, and if the inverter temperature exceeds preset threshold.
(3) For current values when motors include a holding brake, refer to
Kinetix 5300 Servo Drive Control Power Specifications
(4) Peak RMS current allowed for up to 1.0 seconds.