Appendix C Specifications
The table lists power specifications and requirements for the Ultra3000 230V
drives (2098-DSD-030, -075, and -150).
Attribute
2098-DSD-030
2098-DSD-075
2098-DSD-150
AC input voltage
(1)
100…240V rms, single-phase
100…240V rms, three-phase
AC input frequency
47…63 Hz
Main AC input current
(2) (3)
Nom (rms)
230V AC (0-pk) max inrush
28 A
50 A
30 A
50 A
46 A
68 A
Auxiliary AC input current
115V AC (rms) nom
230V AC (rms) nom
115V AC (0-pk) max inrush
(4)
230V AC (0-pk) max inrush
1.0 A
0.5 A
47 A
95 A
1.0 A
0.5 A
47 A
95 A
1.0 A
0.5 A
47 A
95 A
Continuous output current (rms)
10.6 A
24.7 A
45.9 A
Continuous output current (0-pk)
15 A
35 A
65 A
Peak output current (rms)
21.2 A
53 A
106 A
Peak output current (0-pk)
30 A
75 A
150 A
Bus capacitance
2820 µF
4290 µF
7520 µF
Internal shunt resistance
35
16.5
9.1
Shunt on
420V DC
420V DC
420V DC
Shunt off
402V DC
402V DC
402V DC
Bus overvoltage
452V DC
452V DC
452V DC
Internal shunt
Continuous power
Peak power
50 W
4.5 kW
50 W
10 kW
180 W
18 kW
External shunt
Resistance
Continuous power
Peak power
30
(-0/+5%)
2.4 kW
6 kW
16.5
(-0/+5%)
4 kW
10 kW
9
(-0/+5%)
8 kW
19 kW
Energy absorption capability
115V AC input
230V AC input
251 J
139 J
381 J
211 J
669 J
370 J
Continuous power output
115V AC input
230V AC input
1.5 kW
3 kW
—
7.5 kW
—
15 kW
(1) Specification is for nominal voltage. The absolute limits are ±10%, or 88…265V rms.
(2) The 2098-DSD-030
x-xx,
2098-DSD-075
x-xx,
and 2098-DSD-150
x-xx
(200V-class) drives are limited to one contactor cycle per 2 minutes.
(3) Power initialization requires a short period of inrush current. Dual element time delay (slow blow) fuses are recommended.
(4) 400 µs half wave sine.