Rockwell Automation Publication 20P-TG003B-EN-P - September 2021
29
Component Test Procedures
Chapter 2
Table 3 - SCR Anode to Cathode Junction Measurements for Non-Regenerative Drives
Figure 7 - Non-Regenerative Drive SCR Module Layout
On SCR Module…
SCR…
Measure from
Terminal…
To Terminal… Nominal meter reading:
01
01
U
C
“open circuit” or “megaohms” range
04
U
D
02
02
V
C
05
V
D
03
03
W
C
06
W
D
U
V
C
D
W
SCR
Module 01
SCR
Module 02
SCR
Module 03
U
C
V
D
W