Chapter 1
Before You Begin Testing, Maintenance, or Repairs
General Safety Precautions
Read the following precautions before you begin testing components, performing
maintenance or repairing the drive.
ATTENTION:
Only qualified personnel familiar with DC drives and associated
machinery should plan or implement the installation, startup, and subsequent
maintenance of the system. Failure to comply may result in personal injury and/
or equipment damage.
ATTENTION:
This drive contains
ESD
(Electrostatic Discharge) sensitive parts and
assemblies. Static control precautions are required when installing, testing,
servicing or repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with static control
procedures, reference A-B publication 8000-4.5.2, “Guarding Against
Electrostatic Damage” or any other applicable ESD protection handbook.
ATTENTION:
Severe injury or death can result from electrical shock, burn, or
unintended actuation of controlled equipment. Hazardous voltages may exist in
the drive enclosure even with the circuit breaker in the off position.
Recommended practice is to disconnect and lock out control equipment from
power sources. If it is necessary to work in the vicinity of energized equipment,
the safety related work practices of NFPA 70E, Electrical Safety Requirements for
Employee Workplaces, must be followed. DO NOT work alone on energized
equipment.
ATTENTION:
Potentially fatal voltages may result from improper usage of an
oscilloscope and other test equipment. The oscilloscope chassis may be at a
potentially fatal voltage if not properly grounded. If an oscilloscope is used to
measure high voltage waveforms, use only a dual channel oscilloscope in the
differential mode with X 100 probes. It is recommended that the oscilloscope be
used in the A minus B Quasi-differential mode with the oscilloscope chassis
correctly grounded to an earth ground.
ATTENTION:
Remove power before making or breaking cable connections. When
you remove or insert a cable connector with power applied, an electrical arc may
occur. An electrical arc can cause personal injury or property damage by:
•
sending an erroneous signal to your system’s field devices, causing unintended
machine motion
•
causing an explosion in a hazardous environment
Electrical arcing causes excessive wear to contacts on both the module and its
mating connector. Worn contacts may create electrical resistance.
ATTENTION:
HOT surfaces can cause severe burns.
Do not
touch the heatsink
surface during operation of the drive. After disconnecting power allow time for
cooling.