Chapter 2
Installation
3. Form a drip loop in the cable to keep liquids away from the connectors.
4. Verify the continuity and functionality of the thermal switch signals,
TS+ and TS-.
These signals are transmitted through the feedback cable that connects
the motor to its controlling drive.
Change Connector Orientation
You can rotate the circular DIN connector housings up to 180°.
Follow these steps to rotate the DIN connectors.
1. Mount and fully seat a mating cable on the connector.
2. Grasp the connector and the cable plug by their housings and slowly
rotate them to the outside of the motor.
If necessary, repeat these steps for the other connector (feedback or
power/brake).
ATTENTION:
Only apply force to the connectors; do not apply force to the
cable. Do not use tools (for example, pliers and vise-grips) to assist with the
rotation of the connector.
Failure to observe these safety precautions could result in personal injury or
damage to equipment.