3-2
Program Keypad Module
Key Functions
Escape
The ESCape key allows you to toggle between the Display and Program modes.
When the Program mode is active, this key will disable the editing of a parameter
value.
Select
The SELect key enables editing of a parameter value when the Program mode is
active. When you press this key, the Program Mode Indicator flashes.
Up/Down Arrow Keys
Use the Up/Down Arrow keys to scroll through a list of parameters, or
increase and decrease parameter values. Press and hold either key to increase
scrolling speed. Real time frequency adjustment can be achieved when using
P58 - [Internal Frequency]
and
P59 - [Frequency Select]
. Refer to Chapter 5 for further
information.
Enter
Pressing this key causes the current value displayed to be entered into memory
(only while in the Program mode). When you press this key, the Program Mode
Indicator remains on, but stops flashing.
Direction LEDs (Indicators)
The appropriate LED will illuminate continuously to indicate the commanded
direction of rotation. If the second LED is flashing, the drive has been commanded
to change direction, but is still decelerating.
Important:
Actual motor rotation could be different if motor leads are not
connected properly. Refer to Chapter 4 for details on how to verify
correct motor rotation.
Reverse (Change Direction)
This function is only active when
P46 - [Input Mode]
is set to 2. When active, pressing
this key causes the motor to ramp down to 0 Hz and then ramp up to its set speed
in the opposite direction. When the motor is running, pressing this key causes the
(currently illuminated) LED to flash, indicating motor rotation while decelerating
to zero. The other LED will illuminate indicating the commanded direction.
Start
This function is only active when
P46 - [Input Mode]
is set to 2. When active, pressing
this key initiates a start command.
Stop
Pressing the Stop key will cause the motor to stop, using the selected stop mode.
Refer to the
P34 - [Stop Mode]
parameter. If the drive has stopped due to a fault,
pressing this key will clear the fault.
Important:
The Stop key is always active in all control modes.
Содержание Allen-Bradley 160 SSC Series
Страница 12: ...1 6 Getting Started End of Chapter ...
Страница 58: ...5 20 Parameters and Programming End of Chapter ...
Страница 66: ...A 4 Specifications End of Chapter ...
Страница 75: ...Accessories and Dimensions B 9 Drilling Template A Figure B 10 ...
Страница 76: ...B 10 Accessories and Dimensions Drilling Template B Figure B 11 ...
Страница 82: ...C 6 CE Conformity End of Chapter ...
Страница 87: ......