![ROCKET LAB PSC MOTORIZED Lightband MKII Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/rocket-lab/psc-motorized-lightband-mkii/psc-motorized-lightband-mkii_operating-procedure_1472596028.webp)
Copyright PSC
2000781K MkII MLB Operating Procedure
Page 28 of 68
Step
Procedure
Date & Initials
Tech.
QA
8.2.2
Perform the following to operate the test circuit.
1. Turn on the power source output.
2. Verify the oscilloscope trigger is active and ready to acquire data.
3. Activate the timer relay.
4. Verify the following occurred:
4.1. Voltage and current recorded per step 8.1.1
4.2. Measured voltage meets requirement in step 8.1.5 for Channels 1 & 3
4.3. Measured current values are approximately 1/10
th
of applied voltage
for Channels 2 & 4
4.4. Timer relay applies power per step 8.1.7
4.5. Data saves and is readable on a computer
5. If positions or scales were altered to examine data, ensure they are
returned to their original values.
6. Turn off the power source output.
If any parameters are not met, make the required changes and repeat this step.
Any change to the
Stow Power and Measurement Circuit
shall also require re-
running
Stow Test Circuit #1
per section 8.1.
8.2.3
Remove the
Test Circuit: Intermediate
portion of
Stow Test Circuit #2
in Figure
-----N/A-----
Содержание PSC MOTORIZED Lightband MKII
Страница 25: ...Copyright PSC 2000781K MkII MLB Operating Procedure Page 25 of 68 Figure 8 1 Stow test circuit 1...
Страница 37: ...Copyright PSC 2000781K MkII MLB Operating Procedure Page 37 of 68 Figure 9 1 SFF test circuit 1...
Страница 46: ...Copyright PSC 2000781K MkII MLB Operating Procedure Page 46 of 68 Figure 10 1 Deploy test circuit 1...