4. Enable International Roaming
a. Enable International Roaming, corresponding command is: 1023,1
b. Disable International Roaming, use PLMN in SIM, corresponding command is: 1023,0,0 or 1023,0
c. Disable International Roaming, manual, plmn = 46002, corresponding command is: 1023,0,1,46002
5. Set Custom Login
a. Enable Custom Login, retries = 5, interval = 60, request content: 0x313233343536373839, no acknowledge,
corresponding command is: 1024,1,5,60,313233343536373839
b. Enable Custom Login, retries = 5, interval = 60, request content: 0x313233343536373839, acknowledge content:
0xafdecb, corresponding command is: 1024,1,5,60,313233343536373839,afdecb
c. Disable Custom Login, corresponding command is: 1024,0
6. Set Time Wakeup
a. Enable Time Wakeup, time1 = 00:00, time2 = 23:59, corresponding command is: 1027,1,00:00,23:59
b. DisableTime Wakeup, corresponding command is: 1027,0
7. Set Phone Number
a. Add a phone 8613711210511, index is random, enable call reboot and SMS reboot, disable call wakeup
and SMS wakeup, enable SMS control, corresponding command is: 1036,0,+8613711210511,10101
b. Add a phone 8613711210511 in index 2, disable call reboot, enable call wakeup, disable SMS reboot,
enable SMS wakeup, disable SMS control, corresponding command is: 1036,2,+8613711210511,01010
c. Delete a phone number at index 3, corresponding command is: 1036,3
5.4
Modbus Address Mapping
DI and DO:
Address
Description
Value
0x3000 Read/Write Coils
0x3000
DI_0 Status
1: On 0: Off
0x3001
DI_1 Status
1: On 0: Off
0x3002
DO_0 Status
1: On 0: Off
0x3003
DI_0 Clear Count Value
1: Clear Counter Value
0: Return Illegal Data Value
0x3005
DI_0 Start Event Counter
1: Start Event Conuter
0: Return Illegal Data Value
0x4000 Read/Write Registers
0x4000
DI_0 Count Value