Robustel GoRugged M1000 Pro User Guide
RT_M1000 Pro_UG_v01.01
27.12.2011
51 / 59
Confidential
1 - enable
1023
Enable Internal Roaming
cmd,flag,mode,plmn
flag:
0 - disable
1 - enable
*mode:(can be null)
0 - PLMN in SIM
1 - manual
plmn(max 6 bytes)
1024
Set Custom Login
cmd,flag,retries,interval,request,ackno
wledge
flag:
0 - disable
1 - enable
retries: 0 - 60
interval: 5 - 120
request(max 64 bytes): hex
*acknowledge(max 32 bytes and
can be null): hex
1025
Set Custom Keep Alive
cmd,flag,interval,request,acknowledge
flag:
0 - disable
1 - enable
interval: 5 - 1200
request(max 64 bytes): hex
*acknowledge(max 32 bytes and
can be null): hex
1026
Set Custom Logout
cmd,flag,request,acknowledge
flag:
0 - disable
1 - enable
request(max 64 bytes): hex
*acknowledge(max 32 bytes and
can be null): hex
1027
Set Time Wakeup
cmd,flag,time1,time2,time3
flag:
0 - disable time wakeup
1 - enable time wakeup
*time1: 00:00 - 23:59(can be null)
*time2: 00:00 - 23:59 (can be null)
*time3: 00:00 - 23:59 (can be null)
1028
Set Periodically Connect
cmd,flag,interval
flag:
0 - disable
1 - enable
interval: 1 - 1800min
1029
Set Call Wakeup
cmd,flag1,flag2,content
flag1:
0 - disable call wakeup
1 - enable call wakeup
*flag2:(can be null)