3.2.9
Reboot
Since cellular network is not as stable as fixed line, M1000 Pro supports various auto reboot function to keep gateway
working 24x7 without hang up.
Reboot
Note: This function is available under both “Config Mode” and “Normal Mode”.
Item
Description
Default
Time
Tick the
Time
checkbox to allow gateway auto reboot with preset
time schedule every day, support maximum 3 time schedule/day (e.g.
07:00, 11:00 and 23:30 every day).
Disable
Call
Tick the
Call
checkbox to allow gateway auto reboot with incoming
call from specified
Caller ID
(phone number).
The
Caller ID
(phone number) should be specified in “
Phone Book
”
tab by inputting the phone number and tick “
Call Reboot
” checkbox.
Disable
Enable SMS Reply
Tick the
Enable SMS Reply
checkbox to allow gateway send reply
short message after auto reboot by Call Reboot from specified
Caller
ID
(e.g. Reboot ok!).
Note
: Only support text format SMS.
Disable
SMS
Tick the
SMS
checkbox to allow gateway auto reboot with incoming
specified short message from specified
Caller ID
(phone number).
Specified short message is set at
Password
item. (e.g. reboot)
The
Caller ID
(phone number) should be specified in “
Phone Book
”
tab by inputting the phone number and tick “
SMS Reboot
” checkbox.
Disable
Enable SMS Reply
Tick the
Enable SMS Reply
checkbox to allow gateway send reply
short message after auto reboot by SMS Reboot from specified
Caller
Disable