Robustel GoRugged M1000 Pro User Guide
RT_M1000 Pro_UG_v01.01
27.12.2011
34 / 59
Confidential
ID
(e.g. Reboot ok!).
Note
: Only support text format SMS.
Note
:
1.
Time format for Time reboot is 24-hours.
2.
The phone numbers for
Call
and
SMS
function can be set in Phone Book tab.
3.
The
Caller ID
must be written in international format, starting with “
+
” followed by the country code.
4.
If you leave
Caller ID
blank, the gateway will reboot with any incoming call, which may cause unexpected issue.
It is highly recommend setting the
Call ID
.
3.2.10
DI
Type
Logic 0 (OFF)
Logic 1 (ON)
Dry contact
Close to GND
open
This tab describes the Digital Input settings.
Networks
Item
Description
Default
Mode
Mode refers to the status of a digital input channel.
Selected from OFF, ON, OnChange, Event Counter and Null.
OFF: is satisfied for as long as DI remains off
ON: is satisfied for as long as DI remains on
OnChange: triggering alarm when DI trigger the related action
whether it is ON or OFF
Event Counter: under event counter mode
Null: DI disabled
Null
Filtering
Software filtering is used to control switch bounces.
Input from 0 to 10000ms.
0
Count Trigger
Available when DI under Event Counter mode.
Input from 0 to 30000. (0=will not trigger alarm)
0