I Introduction
4
I INTRODUCTION
Manual
This Manual is an integral part of the GAHP-A unit and
must be handed to the end user together with the
appliance.
Recipients
This Manual is intended for:
▶
end user, for appropriate and safe use of the appliance;
▶
qualified installer, for correct appliance installation;
▶
planner, for specific information on the appliance.
Control device
In order to be able to work, the GAHP-A unit needs a control
device (DDC, CCP/CCI or external requests), which must be con-
nected by the installer.
II SYMBOLS AND DEFINITIONS
II�1 KEY TO SYMBOLS
DANGER
WARNING
NOTE
PROCEDURE
REFERENCE (to other document)
II�2 TERMS AND DEFINITIONS
GAHP Appliance/Unit = equivalent terms, both used to des-
ignate the gas powered absorption heat pump GAHP (Gas Ab-
sorption Heat Pump).
TAC = Technical Assistance Centre authorised by Robur.
External request = generic control device (e.g. thermostat,
clock or any other system) equipped with a voltage-free NO con-
tact and used as control to start/stop the GAHP unit.
CCI Controller (Comfort Controller Interface) = optional adjust-
ment device Robur which lets you manage up to three modulat-
ing heat only GAHP units (A, WS, GS).
CCP Controller (Comfort Control Panel) = adjustment device
Robur which lets you manage in modulation mode up to three
GAHP units and all system components (probes, diverter/mixing
valves, circulating pumps), including any integration boiler.
DDC Control (Direct Digital Controller) = optional Robur device
to control one or more Roburappliances (GAHP heat pumps, GA
chillers and AY boilers) in ON/OFF mode.
RB100/RB200 Devices (Robur Box) = optional interface devices
complementary to DDC, which may be used to broaden its func-
tions (heating/cooling/DHW production service demands, and
control of system components such as third party generators,
adjustment valves, circulating pumps, probes).
Heat generator = equipment (e.g. boiler, heat pump, etc..) pro-
ducing heating and/or DHW.
GUE (Gas Utilization Efficiency) = efficiency index of gas heat
pumps, equal to the ratio between the thermal energy pro-
duced and the energy of the fuel used (relative to LCV, lower
calorific value).
First start-up = appliance commissioning operation which may
only and exclusively be carried out by a TAC.
S61/Mod10/W10 Boards = electronic boards on the GAHP unit,
to control all functions and to provide interface with other de-
vices and with the user.
III WARNINGS
III�1 GENERAL AND SAFETY WARNINGS
Installer's qualifications
Installation must exclusively be performed by a Quali-
fied Firm and by Skilled Personnel, with specific knowl-
edge on heating, cooling, electrical systems and gas
appliances, in compliance with the laws in force in the
Country of installation.
Declaration of Conformity
Upon completing installation, the installing firm shall
issue to the owner/client the appliance's Workmanlike
Conformity Declaration, according to national/local
regulations in force and the manufacturer's instructions/
provisions.
Misuse
The appliance must only be used for the purposes for
which it has been designed. Any other use is deemed
hazardous. Incorrect use may affect operation, duration
and safety of the appliance. Adhere to the manufactur-
er's instructions.
Hazardous situations
▶
Do not start the appliance in hazardous conditions,
such as: gas smell, problems with the plumbing/elec-
trical/gas system, parts of the appliance under water