Repeater Wiring:
Connect the Universal Transmitter to a 12V power supply. Connect the
12V, 0V, and RXD (data line) of the Universal transmitter to a Receiver.
INSTALLING A UNIVERSAL TRANSMITTER
Switch 1 - OFF
In this mode the unit will function as a Universal
Transmitter.
Switch 2 - ON
Formatting: Causes the unit to transmit a Code on
input state change.
Switch 2 - OFF
Normal operation.
Switch 3 - OFF
Causes the unit to transmit Roboguard Code during
formatting. Will be programmed into an intruder zone on the receiver.
Switch 3 - ON
Causes the unit to transmit Remote Code during
formatting. Will be programmed into a remote zone on the receiver.
Switch 4 – ON then OFF
Transmitter learns the default input states
(N/O or N/C)
uTx Wiring
:
Connect the uTx to 12V and ground. (+12V, -0V on the unit)
PROGRAMMING ROBOGUARD OR REMOTE CODES.
The uTx can transmit either Roboguard or Remote code.
Switch 2 ON
will make the uTx transmit a code when an input zone is
triggered. Each input zone transmits an individual code so the uTx
behaves like 4 separate Roboguards or Remotes.
Switch 3 OFF
the code transmitted will be Roboguard
Switch 3 ON
the code transmitted will be Remote
Each input Zone on the uTx can take a trigger from normally open or
normally closed devices.
Connect these devices to the uTx via a zone and the common making
sure they remain in their non triggered state.
Turn switch 2 on and select Roboguard or Remote with switch 3