Roboguard
24
The installation involves mounting, wiring, and programming guards,
remotes, and output switches.
Mounting:
Mount the keypad close to the alarm panel or next to the alarm
system’s keypad (depending on whether you want the data output to
go to the System keypad or the System panel). Mount the receiver in a
‘high site’ that will maximise the radio coverage for the installation
area.
Wiring:
Wire the 12V power to the receiver and the keypad and check that the
devices power up.
Connect the receiver data line to the keypad.
Wire the keypad outputs into the alarm panel zones.
See ‘output port
wiring’
.
The switch wiring is dependent upon decisions that are made regarding
the operation of the keypad, see
‘output port programming’
.
Optionally you may choose to wire-in a speaker or an external horn
which will beep for intruder detect. Zone 1, 1 beep, zone 2, 2 beeps
etc.
NOTE:
Reference to ‘beeps’ assumes a speaker is connected.
1.
To enter Roboguard programming mode: hold down the
tamper
button until a beep is heard and the red tamper LED is solid (ON)
You are now in Roboguard programming mode (let go of the button
now). Zone LED’s that already have Roboguards programmed into
them will now be solid (ON).
2.
Press and release the button for the desired zone to be
programmed (only the desired zone LED and the tamper LED
should be ON).
3.
Depress and release
the
tamper lever on
the Roboguard
to send a tamper signal to
the keypad.
4.
The keypad will extinguish all the LED’s
momentarily, 10 beeps will sound and all the
LED’s will flash.
5.
Press any zone button to reset, the
Содержание TRX005