Roboguard
31
Coding
The device will learn any Roboguard code transmitted while in learn
mode.
Activate learn mode by using a conductor (like a screwdriver) to short
out the program pads on the PCB.
The program pads are located between the letter B and the 2-way
DIPswitch on the PCB. (See below)
The status LED will now remain on (solid) until the device learns a valid
roboguard code.
Transmit the desired code (Intruder, tamper or remote).
Remove the conductor.
To confirm the coding, activate the programmed device and check the
output LED
Note:
To send an intruder code, trigger the top and bottom PIR on the
Roboguard while the uRx is in learn mode.
When the code is learned, the status LED will reset back to flashing.
Note:
If the unit is powered up with the programming input shorted,
the unit will erase any learned code.
Configuration
Place the DIP switches in the required positions as per the information
in the connected device’s installer manual and the table below.
Function
ON
N/O
5 minute pulse
OFF
N/C
2 second pulse
Содержание TRX005
Страница 2: ...Roboguard 2 ...
Страница 10: ...Roboguard 10 ...
Страница 12: ...Roboguard 12 ...
Страница 42: ...Roboguard 42 NOTES ...
Страница 43: ...Roboguard 43 NOTES ...
Страница 44: ...Roboguard 44 NOTES ...