HX SERIES
V0212
35
–
English
–
Deutsch
Problems
Troubleshooting causes and solutions Oorzaken en oplossingen
1 The machine does not start when the start switch is activated:
– main switch off;
– power supply failure;
– emergency stop button activated;
– main fuse blown;
– overload activated due to motor overload;
– fault in the electrical system or machine connection;
– planer tables opened and dust chute thicknesser not in position.
2 Reduction of speed when working:
– belt tension not correct;
– motor overload due to incorrect feed speed;
– blunt tools.
3 Vibration of the tools mounted on the spindles:
– the tool is unbalanced; replace or have the balancing done by specialised personal and equipment.
4 Thermal overload does not re-arm automatically after shut-off and cooling down period:
– overload is not set for automatic reset or have the overload is faulty
Adjusting the spindle motor brake
When after extended use of the spindle, the brake down time of the motor exceeds10 seconds the
brake will need to be re-adjusted.
Without removing the motor cowling, put a 5 mm Allen key into the countersunk bolt and turn the bolt
until the air gap between brake and ventilator fan is 0,2 mm.
Make a test run with the motor and check if the brake time is about 8 to 10 seconds.
Electrical components parts list
Q1
Mains isolator switch
N8443
F1/F2/F3
Fuse 10 Amp AM
N8552
F4
Fuse 1 Amp AM
N8554
F5
Fuse 2 Amp AM
N8553
T1
Transformator 400/230V/24V 45VA
N8563
eb1
Thermal overload 230V 1fase
N8477 (12-18 Amp)
eb1
Thermal overload 230V 3 fases
N8475 (5-8 Amp)
eb1
Thermal overload 400V
N8474 (4-6 Amp)
AU1
Emergency stop
N8502
AU2
Emergency stop
N8502
AU3
Emergency stop
N8502
S1
Selector switch
N9435
SE1
Safety switch saw
N9430
SE2
Safety switch planer
N9431
SE3
Safety switch spindle
N9430
LT1
Bulb brake release and 3000 RPM
N8439
LT2
Bulb 6000 RPM
N8439
START
Start button
N8449
STOP
Stop button
N8480
K1
Magnetic starter
N8457
M1
Motor saw 230V 1 fase
M0361
M1
Motor saw 230V 3 fase
M0305
M1
Motor zaag 400V
M0305
M2
Motor planer 230V 1 fase
M0361
M2
Motor planer 230V 3 fase
M0305
M2
Motor planer 400V
M0305
M3
Motor spindle 230V 1 phase
M1461
M3
Motor spindle 230V 3 phase
M1416
M3
Motor spindle 400V
M1415
Содержание HX TZ
Страница 1: ...HX SERIE Manual Betriebsanleitung...
Страница 26: ...HX SERIES V0212 25 English Deutsch Fig 19 Fig 20 Fig 21 1 2 1 3 Vertical pusher Horizontal pusher Wood pusher...
Страница 37: ...36 V0212 HX SERIES English Deutsch...
Страница 70: ...HX SERIES V0212 69 English Deutsch...
Страница 71: ...70 V0212 HX SERIES English Deutsch...
Страница 72: ...HX SERIES V0212 71 English Deutsch...
Страница 73: ...72 V0212 HX SERIES English Deutsch...
Страница 74: ...HX SERIES V0212 73 English Deutsch...
Страница 75: ...74 V0212 HX SERIES English Deutsch...
Страница 76: ...HX SERIES V0212 75 English Deutsch...
Страница 77: ...76 V0212 HX SERIES English Deutsch...
Страница 78: ...HX SERIES V0212 77 English Deutsch...
Страница 79: ...78 V0212 HX SERIES English Deutsch...
Страница 80: ...HX SERIES V0212 79 English Deutsch...
Страница 81: ...80 V0212 HX SERIES English Deutsch...
Страница 82: ...HX SERIES V0212 81 English Deutsch...
Страница 83: ...82 V0212 HX SERIES English Deutsch...
Страница 84: ...HX SERIES V0212 83 English Deutsch...
Страница 85: ...84 V0212 HX SERIES English Deutsch...
Страница 86: ...HX SERIES V0212 85 English Deutsch...
Страница 87: ...86 V0212 HX SERIES English Deutsch...
Страница 88: ...HX SERIES V0212 87 English Deutsch...
Страница 89: ...88 V0212 HX SERIES English Deutsch...
Страница 90: ...HX SERIES V0212 89 English Deutsch...
Страница 91: ...90 V0212 HX SERIES English Deutsch...
Страница 92: ...HX SERIES V0212 91 English Deutsch...
Страница 93: ...92 V0212 HX SERIES English Deutsch...
Страница 94: ...HX SERIES V0212 93 English Deutsch...
Страница 95: ...94 V0212 HX SERIES English Deutsch...
Страница 96: ...HX SERIES V0212 95 English Deutsch...
Страница 97: ...96 V0212 HX SERIES English Deutsch...