Charging/discharging after an input electricity cut
25
General
- The Overloader2 is equipped with a protection function, which keeps the unit going with
the same process that was running before the input electricity cut. This is especially
important for racing. There is always the possibility of a short time electricity cut-off in the
drivers pit area. The Overloader2 insures, that you are not missing a race due to a half
empty battery after such an electricity cut in the pits.
- This function is always active and cannot be switched off.
- This function is working for charging, discharging and cycling.
- The charge or discharge process after an input electricity cut is always running with the
original (before the original start of the process) parameter adjustments. Later made changes
(e.g. amperage) will not be taken into account.
- All the process information (charge or discharge graphs, capacities, average voltage, internal
resistance readings) will be still available, but minor allover errors in these figures are
possible (but not more than the records from the last 60 seconds before the input electricity
cut).
- The records from the currently running cycle will be available, but the information from
earlier cycles will be lost.