Application:
Sensor 2 is used as a level checker (e.g., LC-N 24V DC).
Relay K1 operates an indicator light: Bowl feeder or linear feeder empty.
4.5.5. Code C008 cycle monitoring
Objective:
Monitoring of sensors 1 (accumulation check) and/or 2.
When activating the cycle monitoring function, the "AND, SOL" links in code C006 must not be activated!!!
Select code
KANAL l
KANAL 2
CODE
Set code
Code C008
KANAL l
KANAL 2
CODE
Sensor input 1 is monitored
KANAL l
KANAL 2
CODE
I = active
0 = not active
Sensor input 2 is monitored
KANAL l
KANAL 2
CODE
I = active
0 = not active
Monitoring depending on
Channel 1
KANAL l
KANAL 2
CODE
I = active
0 = not active
Time till alarm comes up
KANAL l
KANAL 2
CODE
3 - 240 sec.
Switching off channel 1
KANAL l
KANAL 2
CODE
I = see below
0 = see below
Switch
KANAL l
KANAL 2
CODE
I = Alarm on relay K1
0 = Alarm on relay K2
Return
KANAL l
KANAL 2
CODE
Save and return to
main menu
The cycle watchdog monitors the CLEAR sensor status. The time (A 180) sets the maximum duration
for which a sensor is allowed to be clear before an alarm message is generated.
In case of an alarm the relay K2 is clocked on and off. Reset takes place automatically when the
sensor is operated again.
If OUT = 1 the alarm operates relay K2 (indicator light: Error) and the bowl feeder or linear feeder is
stopped. An ERROR message appears on the operator panel display.
Use the bottom right cursor button for reset.
If OUT = 0 the alarm only operates relay K2 (indicator light: Error). Reset takes place automatically
when sensor 1 is operated.
If A.I. = 1 relay K1 is clocked on and off in response to the alarm (switching from relay K2 to relay K1).
4.5.6. Code C009 Show status / Reset ERROR message
Objective:
Checking of the set vibrating frequency and of the sensor inputs.
Select code
KANAL l
KANAL 2
CODE
Set code
Code C009
Clear Error
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
Reset error message
External enabling signal
Channel 1
KANAL l
KANAL 2
CODE
I = active
0 = not active
Signal at sensor input 1
KANAL l
KANAL 2
CODE
I = active
0 = not active
Signal at sensor input 2
KANAL l
KANAL 2
CODE
I = active
0 = not active
Return
KANAL l
KANAL 2
CODE
Save and return to
main menu