6.4 Fault table
Fault description
Cause
Remedy
Personnel
High noise production
Grooved ball bearing in the
pulley box is damaged
Replace the grooved ball
bearing.
Assembly staff
Rollers are damaged
Replace rollers.
Assembly staff
Timing belt is worn
Replace the timing belt.
Assembly staff
Normal operating noises from
the polyurethane timing belt
Treat timing belt with lubri-
cating spray.
Assembly staff
Guide shafts are corroded
and dirty
Insufficient lubrication
Contact RK Rose
+Krieger GmbH.
Assembly staff
Timing belt is overstret-
ched
Timing belt is overloaded, e.g.
due to a blockage
Contact RK Rose
+Krieger GmbH.
Assembly staff
6.5 After maintenance and troubleshooting
Perform the following steps once maintenance and troubleshooting
are complete:
1.
Check that all screw connections loosened previously are
secure.
2.
Ensure that all tools, materials and other equipment used
have been removed from the work area.
3.
Clean the work area and remove any escaped substances
such as liquids, processing material or similar products.
Maintenance and troubleshooting
After maintenance and troubleshooting
14.10.2021
Linear unit RK MonoLine R/RK MonoLine Z
114