5.4.4 Assembling the limit switch
5.4.4.1
Assembling the mechanical limit switch
Version
RK MonoLine R, Z
Size
40
Personnel:
n
Assembly staff
Protective equipment:
n
Protective clothing
n
Protective gloves
n
Safety shoes
Prerequisite:
n
The electric gear unit and/or motor (if available) are secured
against restarting.
1.
Insert and position the slot stones (Fig. 33/1) in the slot of the
guide carriage.
2.
Place the actuator (Fig. 33/2) at the height of the inserted slot
stones.
3.
Tighten 2 screws (Fig. 33/3):
Size
Screw size
Tightening torque [Nm]
40
M4
2
4.
Insert and position the slot stones (Fig. 34/1) in the slot of the
guide profile.
5.
Place the limit switch (Fig. 34/4) along with a mounting
bracket (Fig. 34/3) at the height of the inserted slot stones.
6.
Tighten 2 screws (Fig. 34/2):
Size
Screw size
Tightening torque [Nm]
40
M4
2.1
ð
The limit switch is assembled.
Applicable to
Assembling the actuator
Fig. 33: Assembling the actuator
Assembling the limit switch
Fig. 34: Assembling the limit switch
Assembly
Assembling optional modules > Assembling the limit switch
14.10.2021
Linear unit RK MonoLine R/RK MonoLine Z
107