Rittal Liquid Cooling Package
75
16 Further technical information
EN
16.2 Characteristic curves
16.2.1 Cooling output
All information in the diagrams refers to the use of pure
water as a cooling medium. The cooling performance
data when using a water-glycol mixture is available on
request from Rittal.
Fig. 78:
Cooling output of the LCP Rack/Inline in the "30 kW" version
Fig. 79:
Cooling output of the LCP Inline flush
LCP Rack/Inline 3311.138/238/538 (15 ºC water inlet, 60 l/min)
0
5
10
15
20
25
30
35
1
2
3
Number of fans in LCP
Cooling output [kW]
LCP Inline flush 3311.148/548 (15 ºC water inlet)
10
15
20
25
30
35
2
3
4
Number of fans in LCP
Cooling output [kW]