Operating Manual. Contact GSM-9N

/А/М

Figure 7.  Configuring the CSD connection in the ritm.conf software

Figure 8.  Configuring the CSD connection in the Ritm Configure

Содержание Contact GSM-9?

Страница 1: ...Saint Petersburg 2017 Control panels Contact GSM 9N Contact GSM 9 Contact GSM 9 Operating Manual Rev 1 0...

Страница 2: ...ion 19 Selecting and Installing SIM cards 19 Installation and connection 20 Installation Procedure 20 Indication 22 Contact GSM 9N 22 Contact GSM 9 24 Contact GSM 9 25 Standalone configuration 26 Pane...

Страница 3: ...odes 64 Touch Memory keys 68 Output terminals 72 Engineering Numbers 74 SMS messages 76 History 78 Update 81 Service 83 Adding to GEO RITM 85 Maintenance 87 Safety Measures 88 Transportation and Stora...

Страница 4: ...and logically dedicated part of a security system Monitoring server A server to which the device transmits data through configured communication channels Tamper A contact located under the device cov...

Страница 5: ...are designed for setting up security at remote real estate objects apartments offices country houses and other real estate objects This manual contains data on the design principle of operation prope...

Страница 6: ...other objects Messages to the monitoring software are transmitted via GSM network through GPRS CSD SMS channels The panels features are the following Connection up to 3 hardwired zones of dry contact...

Страница 7: ...ensor Transmitting messages to the monitoring software or to a user using the Ademco Contact ID protocol specify the names of areas and zones directly in the software settings Event history All events...

Страница 8: ...se configuration software 3 Remotely using CSD modem Partial panel setup without using PC1 The Contact GSM 9N panel could be partly setup in standalone mode In this case the setup is performed with a...

Страница 9: ...on device connection 2 outputs of the panel can host a number of various actuation devices such as sirens illuminated panels and indicators Hardwired zones The panel allows to connect up to 3 dry cont...

Страница 10: ...M antenna 2 With external GSM antenna In this case the device has a connector for the antenna SMA connector on the fig 1 Figure 1 XS1 SA1 TM LED GND 1 2 3 ZONES STAY ZONES EXIT BYPASS CANCEL ARMED INS...

Страница 11: ...tatuses of areas assigned to the EXIT button is connected to terminals 1 and U OK A siren is connected to 2 and U OK terminals TM LED GND Terminals for Touch Memory reader connection TM output positiv...

Страница 12: ...Ah enclosure The panel is equipped with a built in Touch Memory reader and a visual frame with Armed Battery and Ready indicators Figures 2 3 and 4 show panel circuit board design and dimensions of en...

Страница 13: ...www ritm ru 13 of 93 Operating Manual Contact GSM 9N Figure 3 ARMED BATTERY READY Contact 1 2Ah enclosure Figure 4 ARMED BATTERY READY Contact 7Ah enclosure...

Страница 14: ...d acid battery connector The GND terminal is negative and the BAT terminal is positive for the battery TM LED GND Terminals for Touch Memory reader connection TM output positive terminal for connectin...

Страница 15: ...made in plastic enclosure and has 2 versions 1 Contact GSM 9M TM control panel is equipped with a Touch Memory key reader built in the enclosure 2 Contact GSM 9M TM control panel is equipped with a RF...

Страница 16: ...www ritm ru 16 of 93 Operating Manual Contact GSM 9N Figure 6 Contact GSM 9...

Страница 17: ...n the enclosure optionally depending on the version 8 Spring contacts Spring contacts are connected to the indication board on the top cover of the enclosure 9 Battery location Backup battery compartm...

Страница 18: ...ct GSM 9 version Max number of TM keys pcs 16 Number of events in history 65 535 Configuring parameters using PC Yes GSM signal strength indication using keypad for Contact GSM 9N version Number of ba...

Страница 19: ...el 2 The GPRS session opening is not charged 3 The traffic is charged at the end of the day session 4 The rounding threshold for the traffic charging is the lowest Selecting and Installing SIM cards T...

Страница 20: ...lines Heaters and ventilation systems Protect the panel from moisture 1 Open the panel enclosure 2 Run all wires through an opening in the enclosure back cover 3 Securely fasten the back enclosure cov...

Страница 21: ...ply to the power terminals 12 GND of Contact GSM 9N circuit board i If the contact GSM 9N panel is connected to a Ritm power supply connect the wire from the CPW terminal of power supply to the CPW te...

Страница 22: ...med areas is not normalized or all areas are armed FIRE3 On Risk of fire one fire detector triggered Blinking Fire alarm two or more fire detectors triggered Off Fire areas are normal INSTANT On Devic...

Страница 23: ...ZONES 1 16 The Zones button is pressed States of zones 1 6 are shown Off Zone is OK On Zone with fire alarm3 is possible in zone Blinks slowly Zone in fire3 alarm Blinks rapidly Zone failure The Zone...

Страница 24: ...re protection areas and 24 hours BATTERY On The panel is powered from the battery Off The panel is powered from the main power supply 220V READY On All zones in non armed areas are normal Off At least...

Страница 25: ...Off All areas are disarmed excl fire protection areas and 24 hours blue On The panel is powered from the battery Off The panel is powered from the main power supply 220V blue On Operational power 12V...

Страница 26: ...2 Upon entering a command device indicators 1 5 lights up Indication designation is the following the indicator 1 is on the signal strength is 20 the indicators 1 and 2 are on the signal strength is 4...

Страница 27: ...e 0 under no duress 1 under duress A numbers of arming areas from 1 to 6 For example 1234 4 1 22220 123456 In this example a new value of 2222 for arming areas 1 2 3 4 5 and 6 with no duress is assign...

Страница 28: ...onnect to the panel you can use remote GSM CSD connection or a USB2 PC connection cable CSD connection i To establish a CSD connection use a GSM modem connected to the PC Before using the multiuse con...

Страница 29: ...www ritm ru 29 of 93 Operating Manual Contact GSM 9N Figure 7 Configuring the CSD connection in the ritm conf software Figure 8 Configuring the CSD connection in the Ritm Configure...

Страница 30: ...n program GSM modem_Ritm Drivers zip To connect to the panel please specify the following settings in the configuration software properties Connection type USB COM cable COM port COM port number to wh...

Страница 31: ...SB connection in the Ritm Configure software i Use the Device Manager to identify the port number used by the operating system In the Ports section find the port name Silicon Labs CP210xUSB to UART Br...

Страница 32: ...www ritm ru 32 of 93 Operating Manual Contact GSM 9N Figure 11 Driver Check...

Страница 33: ...card tab Equipment Fig 12 Under the panel image click Device Setup Figure 12 Configuring the panel using GEO RITM Configuration using Ritm Link To access the configuration software via RITM Link cloud...

Страница 34: ...ll specified settings are reset Figure 14 The Save changes button The configuration software window is separated into the following areas Fig 15 1 Configuration software sections 2 Settings section 3...

Страница 35: ...Operating Manual Contact GSM 9N Figure 15 Configuration software window...

Страница 36: ...unauthorized access to panel configuration Default value 1234 GSM signal level SIM 1 2 Shows the current level of GSM signal To connect to the network and update GSM signal level details click the Tes...

Страница 37: ...Operating Manual Contact GSM 9N Figure 16 Global Settings section...

Страница 38: ...ecting the panel s operability are generated i System events are recorded with 0 as the zonenumber and 0 as the area number Generate a daily autotest i An automatic test is a special event generated b...

Страница 39: ...is off and a backup power supply voltage drops down to 11V i Note in 3 hours after power supply the 302 3 Rcv Battery discharge is generated Generate the events 220V failure recovery Set the period ov...

Страница 40: ...dentify which mode is used for panel configuration the zone encodes the following details 0 configuration via cable 99 configuration over CSD channel using the phone number not marked as an Engineerin...

Страница 41: ...Operating Manual Contact GSM 9N Figure 17 System Events section...

Страница 42: ...ses a predefined set of providers To view them click Additionally When disabling the Specify APN configuration automatically please specify GPRS phone number GPRS activation number normally 99 Access...

Страница 43: ...tion min Set the value of the pause between connection attempts via Online channel During this pause the data may be transferred via Offline communication channels see section Communication channels a...

Страница 44: ...Operating Manual Contact GSM 9N Figure 18 GPRS parameters section...

Страница 45: ...ipient in case one of the channels is failed Communication channels are combined to form the direction using the OR switch and the directions are separated using the AND switch i It is a common practi...

Страница 46: ...monitoring software Check connection with server in GPRS Online channel in Upon operation through a GPRS TCP IP communication channel via SIM1 SIM2 specify a rate for sending PING command to the monit...

Страница 47: ...monitoring software server only to transfer the events and disconnects after the events have been transferred ContactID via digital channel GSM V 32 110 SIM1 SIM2 Intented to transfer events to a Con...

Страница 48: ...Operating Manual Contact GSM 9N Figure 19 Communication channels section...

Страница 49: ...one another but only one hardwired zone type can be used at a time The used hardwired zone type is defined in this section using the Resistive Dry contacts switches Troubleshooting code Regardless of...

Страница 50: ...fire hardwired zones 5 Entrance delay sec If the hardwired zone is used to connect entry area sensors indicate the time in seconds which the user will have to disarm the area without activating the al...

Страница 51: ...Operating Manual Contact GSM 9N Figure 20 Hardwired zones properties section...

Страница 52: ...p properties of existing areas A unique area number from 1 to 6 The area number allows to identify the room in which the alarm has been tripped Area state This field shows the current state of the sys...

Страница 53: ...o connect fire sensors set the fire areas Fire areas are instant Hardwired zones processing logic also changes if two hardwired zones are in a violated state an event 110 1 Alarm Fire is generated If...

Страница 54: ...the counter resets If there are no need to limit the number of generated events set the value to No limitations Arming without connection to the server Allow arming if no connection to the server The...

Страница 55: ...Operating Manual Contact GSM 9N Figure 21 Areas Configuration section...

Страница 56: ...n the hardwired zones To configure the resistance of the hardwired zones for every type of sensors individually To use fire sensors7 If the resistors from the delivery package are used for connection...

Страница 57: ...e position of the lower indicators located under the resistance scale for the hardwired zone The color of each indicator corresponds to a part of the hardwired zone on the resistance scale which it af...

Страница 58: ...larm Zone 1 Alarm Zone 2 Alarm Zone 1 2 Short circuit Configure the operating thresholds trigger each sensor one by one the first the second both sensors the breakage and its short circuit and use the...

Страница 59: ...Operating Manual Contact GSM 9N Figure 24 Hardwired zones settings resistive hardwired zones...

Страница 60: ...an enable only one security sensor i Please note For dry contact hardwired zones the operating thresholds are not configured When using the dry contact hardwired zone the areas can not be fire see sec...

Страница 61: ...Operating Manual Contact GSM 9N Figure 25 Hardwired zones settings dry contacts...

Страница 62: ...rm certain outdoor areas using the Perimeter button without entering the user code indicate them from the drop down list Normally arming using the Perimeter button is used when a user wants to stay in...

Страница 63: ...Operating Manual Contact GSM 9N Figure 26 Keypads section...

Страница 64: ...er address or combinations like 0000 or 1234 Do not tell your combinations to third parties Keep the code in a secure place or remember it which is better Adding a new user code To add the code click...

Страница 65: ...re armed after entering of the user code including the duresse code an event 402 3 Arming the area is generated When the areas are disarmed except using the duresse code the 402 1 Disarming the area e...

Страница 66: ...ser code D A where Code numder a code index digit from 0 to 9 0 refers to 10 D duresse 0 under no duress 1 under duress A numbers of arming areas from 1 to 6 For example 1234 4 1 22220 123456 To inter...

Страница 67: ...Operating Manual Contact GSM 9N Figure 27 Keypad codes section...

Страница 68: ...equency of 1 time per second alarm in the area Adding a new key To add a new TM key to the system click Add type 16 digit key number or touch the key to the TM reader and click Read the key Additional...

Страница 69: ...ed by its one time application i Note that if you connect at least one smart reader to the panel all other connected readers start working according to the logic of smart one they will support the dou...

Страница 70: ...armed Blinking Alarm in any area incl fire protection areas and 24 Off At least one of security areas is not armed i The alternating flashing of yellow and red indicators no more than 5 seconds means...

Страница 71: ...Operating Manual Contact GSM 9N Figure 28 Touch Memory Keys section...

Страница 72: ...ypads For Contact GSM 9A M duplicates the condition of the selected areas parameter Indication of area status OK2 output OK1 output is designed to connect the siren Operation mode of the siren is conf...

Страница 73: ...Operating Manual Contact GSM 9N Figure 29 Outputs section...

Страница 74: ...hone number To enable configuring of the panel from specific engineering phone numbers only fill in the blank fields in this section in the format used by the communications provider For example and c...

Страница 75: ...Operating Manual Contact GSM 9N Figure 30 Engineering Numbers section...

Страница 76: ...ipher therefore it should be brought into the form Disarming area 1 using the key 2 The manufacturer settings allow using SMS for the user without additional setup If an event needs to be clarified pi...

Страница 77: ...Operating Manual Contact GSM 9N Figure 31 SMS messages section...

Страница 78: ...recovery Event shows the description of an event Area is the number of the area in which the event has been generated Hardwured zone or TM is the number of a hardwired zone user code key involved in...

Страница 79: ...xt format To do that specify the number of entries and read them clicking the Read the records link After that click the link Export of the read history to txt Deleting history To delete the history f...

Страница 80: ...Operating Manual Contact GSM 9N Figure 32 History section...

Страница 81: ...date version download and install all previous versions To update the panel software follow the following steps 1 Select a firmware version to update 2 Click Start updating to begin downloading the so...

Страница 82: ...Operating Manual Contact GSM 9N Figure 33 Updates Section...

Страница 83: ...k the Read settings from the device link and wait for the loading to finish After this click the Save settings into the file link and specify where you wish to save the file Use the settings file to a...

Страница 84: ...Operating Manual Contact GSM 9N Figure 34 Service Section...

Страница 85: ...e wizard hints during the registration procedure In case of questions please refer to GEO RITM document User Manual Log into your account In the main menu select the Stationary Objects section Click A...

Страница 86: ...Operating Manual Contact GSM 9N Figure 36 GEO RITM Service...

Страница 87: ...ing Manual Contact GSM 9N Maintenance At least once per month check SIM card accounts for funds At least twice per year visually inspect the panel for enclosure or connector damages Clean the terminal...

Страница 88: ...www ritm ru 88 of 93 Operating Manual Contact GSM 9N Safety Measures All setup and maintenance activities applied to the panel should be performed by duly qualified personnel...

Страница 89: ...ckaging in closed vehicles Storage conditions should conform to those listed in 1K1 under EN 60721 3 1 Transportation conditions should conform to those listed in 1K1 under EN 60721 3 2 Storage premis...

Страница 90: ...tion Although the warranty exploitation period is 12 months from the commissioning date it may not exceed 18 months from the production date The warranty storage period is 6 months from the production...

Страница 91: ...ting Manual Contact GSM 9N Contact Details Main office Moscow office Saint Petersburg Russia 195248 Moscow Russia 127051 pr Energetikov 30 bld 8 2 Kolobovskiy per 13 14 7 812 325 01 02 7 495 609 03 32...

Страница 92: ...us metals dangerous or toxic substances possible to harm to health or environment and does not pose a hazard to life health or environment after expiration of term of service Therefore panel disposal...

Страница 93: ...www ritm ru 93 of 93 Operating Manual Contact GSM 9N Change history Revision Revision date Description 1 0 25 04 2017 Full revision of document...