background image

Mastering Your System 

 

 Page 

15 

 

2-Way 8 Button Remote Control:

  

Using the bi-directional 8 button remote control you can set, 
unset, send a panic alarm, activate outputs and more. Being bi-
directional the remote control receives a reply status indication, 
via its 3 colored LEDs and internal buzzer sounder, from the 
panel for each command that it has sent to the panel. For higher 
security, commands can be defined to be activated with a 4 digit 
PIN code.

 

 

Smartphone Operations: 

Homeowners can now enjoy the iRISCO Smartphone App for 
smart and easy control of their LightSYS2 system. The app 
enables users to set/unset the system on-the-go, activate home 
automation devices, omit detectors, view the system’s status and 
history, and much more. Available for iPhone, iPad and Android. 

Note:  

Registration and connection of your system to 

www.riscocloud.com may depend on your engineer

 

 

Web Application

RISCO Group’s interactive web application enables you to 
monitor, control and configure your LightSYS2 system from any 
location. As with the Smartphone app, the application is powered 
by the RISCO Cloud server. 

Note:  

Registration and connection of your system to 

www.riscocloud.com may depend on your engineer

 

 

4 Button Keyfob:

Using the wireless 4 button keyfob you can set, unset, send a 
panic alarm and activate outputs. 

 

Remote Phone Operation:

  

If your system includes the voice module, it can provide audible 
information about system status, and enable any remote, 
touch-tone (DTMF) telephone to act as a keypad for the system. 
Upon event occurrence, such as alarm activation, the voice 
module informs you by calling you and playing a prerecorded 
event announcement, as described in the 

5IN1545 LightSYS Voice 

Module Programming and Operations Guide.

 

Содержание LightSYS2

Страница 1: ...User Manual ...

Страница 2: ......

Страница 3: ...Complete registration form and click Register 7 To complete registration open the email message received on the email account you defined as Login Name Login to RISCO Cloud 1 Go to www riscocloud com 2 Enter User Name and Password same as supplied during the registration process 3 Enter Passcode PIN LightSYS2 User Code 4 Click Enter iRISCO RISCO s Smartphone Application Homeowners can now enjoy th...

Страница 4: ...essing simultaneously for 2 seconds Fire Alarm Pressing simultaneously for 2 seconds Medical Alarm Pressing simultaneously for 2 seconds Quick Zones Omit Code Zone No Activate Output Code Activities Util Output Num Define Follow Me Code Follow Me Define View Fault Code View Fault View Event Log Code Event Log Keypad Chime On Off Code Activities Keypad sound Chime Edit User Code Code Codes Tags Def...

Страница 5: ...tion Unset Select partition 1 2 3 4 and press followed by Code Panic alarm Press simultaneously for 2 seconds Fire alarm Press simultaneously for 2 seconds Emergency Med alarm Press simultaneiously for 2 seconds Status Request Press for 2 seconds to view LED display of system status see Indicators below Press for 2 seconds followed by code2 to view LED display of system status see Indicators below...

Страница 6: ...anic Alarm simultaneously for 2 seconds Clear Operation For Partial setting with no entry delay press and hold for two seconds Notes 1 Consult your engineer for the operations defined with a code 2 The proximity tag can be used instead of code 3 For Partial Setting with no entry delay press for 2 seconds 4 Light sensor is used to save battery by turning on off the keypad backlight 5 Needs to be de...

Страница 7: ...Page 7 Smartphone Full Set System Full Set Partition Partial Set System Partial Set Partition System Unset Code Partition Unset Detector Omit On Off toggle ...

Страница 8: ...s Edit Delete and ADD NEW USERs Web interface users and codes EDIT user fields and access credentials Change Password Enter Old New Confirm SET NEW PASSWORD Quick Zone Omit Select ZONE xx Omit Update Change Appearance Select Color Scheme Alerts Add New Contact Enter Name Email Mobile phone Select Alert Language Partition association and toggle Set Unset Email and SMS Time Zone Select system time z...

Страница 9: ...d Partition Set Press button or button 4 if defined SMS For a full list of SMS operations refer to Appendix D SMS Operation Full Set Code S example 1234S Full Unset Code US example 1234US Part Set Code P example 1234P Partition Set Code S Partition No examples To set partitions 1 1234S1 To set partitions 1 and 2 1234S12 Partition Unset Code US Partition No Example 1234US1 ...

Страница 10: ...it zones Fire On Fire alarm Off No fire alarm Flash Fire fault Proximity Touchscreen only Flashing Indicates keypad has a proximity reader 2 way Slim Keypad LED Indicator Color State Status Blue Blink During communication with the panel Red On Slow flash Rapid flash System fully or partially set During exit delay During alarm Green Blink Fault indication in the system while the system is unset Gre...

Страница 11: ... Capabilities 29 Emergency Alarms 29 Chapter 3 User Functions and Settings 30 User Codes 30 Proximity Tags 33 Setting and Changing System Time and Date 35 Setting Follow Me Destinations 36 Omitting zones 37 Scheduling Weekly Programs 38 Macro Keys 40 Parking Control with LightSYS2 Gate Control Keyfobs 41 Complete List of User Functions 43 Appendix A System Faults 49 Appendix B Glossary 50 Appendix...

Страница 12: ...YS2 contains a variety of programming features including smartphone apps and web control Ask your engineer which features have been programmed for your system This manual describes how to operate your system It will guide you through programming instructions for main system features as well as basic setting and unsetting commands for the system Main System Capabilities Up to 32 sensor devices 30 U...

Страница 13: ...he premises which provide external perimeter and internal burglary protection The system is supervised meaning that the panel checks the status of each sensor to detect problems If a fault is detected you are notified both with panel beeps and indicator lights as well as remote messaging The following diagram shows the components that make up the system ...

Страница 14: ...sed supplementary modules you can operate your system via the following LightSYS2 Keypad and proximity tag Locally through its LCD keypad s you can issue commands to your system In turn the system can communicate information to you through its display indicators and by the sounds it makes 2 Way Slim Keypad With support for up to three bi directional wireless communication 2 Way slim keypads LightS...

Страница 15: ... Android Note Registration and connection of your system to www riscocloud com may depend on your engineer Web Application RISCO Group s interactive web application enables you to monitor control and configure your LightSYS2 system from any location As with the Smartphone app the application is powered by the RISCO Cloud server Note Registration and connection of your system to www riscocloud com ...

Страница 16: ...stem event occurs the control system sends a message to your monitoring service Alarm Receiving Centre describing the exact nature of the event This enables the monitoring service to perform the required action Monitoring service notification can be implemented through either regular telephone cellular communication or IP network A sensor detects The control system An alarm is generated and the is...

Страница 17: ...ng the LightSYS2 voice module This module also enables the LightSYS2 to announce various local messages to residents SMS messaging requires the use of the LightSYS2 GSM GPRS module Email messaging requires the use of the LightSYS2 IP module LCD Status Display The LCD status display will vary depending on the number of partitions in your system If your system is defined with only one partition the ...

Страница 18: ... Fire Alarm Rapid beeping Rapid beeping YES staggered Keypad Police Emergency No sound 1 No sound 1 No Sound 1 Keypad Emergency Medical A momentary chirp No sound No sound Setting or Unsetting No Sound System is set 1 chirp System is unset 2 chirps keyfob Unset after alarm 4 chirps Keyfob System is set 1 chirp Confirm Operation A one second tone if completed correctly No sound No sound Reject Oper...

Страница 19: ...s type of alarm 2 Keypad beeps may be disabled at the user s discretion see Buzzer On Off page 44 3 Press for two seconds to stop the fault beeps 4 Any intrusion zone if selected for the chime feature will when violated during the unset period cause the keypad to annunciate the event The chime can also be disabled when not required ...

Страница 20: ... in the system is assigned to a particular partition meaning that commands entered in a keypad are implemented only in the partition to which it is assigned For example pressing the Quick Set key on a keypad assigned to partition 1 sets only partition 1 Setting your system Setting your system causes the intrusion detectors to trigger an alarm when violated You can set your system by code setting i...

Страница 21: ...is used when leaving the premises Once you have set the system exit via the designated final exit door To fully set your system 1 Verify that the system is ready to be set 2 Enter your user code followed by or hold the tag close to the keypad s keys 3 Leave the premises and close the door The keypad beeps and the icon flashes while the system counts down the exit delay time period 4 When the exit ...

Страница 22: ...on of the others Partitions can be set and unset one at a time or all at once and each partition can be set as Partial Set or Full Set Only users who have been defined to operate multiple partitions can operate more than one partition and simultaneously set unset all partitions To set specific partitions 1 Verify that the system is ready to set 2 For Full Set enter your user code followed by or ho...

Страница 23: ...ll partitions sharing the zone s are set The common zone s is unset if any of the partitions to which the zone s is assigned are unset If the system is defined to work in area mode the common zone will be set if any partition sharing the zone is set The common zone will be unset if all the partitions sharing the zone are unset Group Setting Group setting enables you to set a number of zones within...

Страница 24: ...h Faults in the System If required and defined by your engineer all faults in the system may require confirmation to enable the setting operation When trying to set the system with faults the display will show the system faults Scroll through the list of faults using the key At the end of the list the following question will appear Override Fault Use the key to toggle the option to Y and press Key...

Страница 25: ... period has begun 2 Before the entry delay time period expires enter your user code followed by or present the proximity tag Note 1 If you make a mistake entering your user code the keypad produces three short beeps If so simply re enter the above sequence correctly 2 If defined by your engineer system sounders sounding two sounder chirps indicate that the system is unset Partition Unsetting Parti...

Страница 26: ...ll sound four sounder chirps indicating that an alarm occurred in the system c If your system is equipped with the voice module an announcement message will be broadcast Alarm occurred in the system 4 Scroll through the list of alarm zones To exit the alarm memory mode before the timeout has expired press which will clear the alarm memory or which will not clear the alarm memory 5 If required proc...

Страница 27: ...allation company can configure the reset of the system to a normal operation mode to require the intervention of your alarm receiving centre or engineer In this case after an alarm condition the system will be regarded as not ready and the display will show a Call Installer message Consult your engineer regarding whether your system reset mode is Remote or Installer Note Before attempting to reset...

Страница 28: ...m Confirm with your engineer which of the user codes is defined as a duress code Note Under no circumstances must the duress code be used haphazardly or without reason Alarm receiving centres along with police departments treat duress codes very seriously and take immediate action Disabling a Fire Alarm Switch Auxiliary Unsetting the fire alarm interrupts the power supplied to the system s smoke d...

Страница 29: ...one call to or from the system and interacting with voice menus that guide you through your required remote operation For detailed information refer to the LightSYS Voice Module Instructions Emergency Alarms Your keypad provides three sets of emergency keys which can be pressed whenever the police fire department or auxiliary assistance is required Police Emergency Pressing simultaneously and for ...

Страница 30: ...rminates commands and confirms data to be stored Used to browse through the menu Scrolls up a list or moves the cursor Changes data Numerical keys are used to input the numeric codes that may be required for setting unsetting or used to activate specific functions User Codes To perform many of the LightSYS2 functions a security code often called a user code must be input LightSYS2 can support up t...

Страница 31: ...ER except that when unsetting the system a duress alarm message is sent to the alarm receiving centre SET ONLY Setting one or more partitions Set only codes are useful for workers who arrive when the premises are already open but because they are the last to leave are given the responsibility to close and secure the premises at the day s close CLEANER Used only for one time setting and unsetting a...

Страница 32: ...d from the web application To set change a user code 1 Press and enter your code followed by 2 Using the arrow keys scroll to the option Codes Tags and press 3 Scroll to Define and press 4 Select the user index number and press 5 Select Edit Code and press Note In the LightSYS2 system the User Index number range is from 00 to 15 00 Grand master 6 Enter the new code followed by If successful a sing...

Страница 33: ...characters available for that key Key Data Sequence 1 1 _ 2 2 a b c A B C 3 3 d e f D E F 4 4 g h i G H I 5 5 j k l J K L 6 6 m n o M N O 7 7 p q r s P Q R S 8 8 t u v T U V 9 9 w x y z W X Y Z 0 0 Use these keys to toggle forwards and backwards through all the available characters Proximity Tags The proximity keypad enables you to use a proximity tag to set and unset the security system or to act...

Страница 34: ...conds approach the proximity tag at a distance of 4 cm from the front of the keypad bottom The keypad automatically reads the proximity tag and saves it into the system s memory Once the proximity tag has been successfully recorded a long confirmation beep sounds and a confirmation message is displayed If the proximity tag is already stored in the system s memory the following message is displayed...

Страница 35: ... 2 Using the arrow keys scroll to the option Codes Tags and press 3 Scroll to Del By Tag and press 4 Within 10 seconds approach the proximity tag at a distance of 4 cm from the front of the keypad bottom If the proximity tag was deleted the following confirmation message is displayed USER TAG XX DELETED If the system does not recognize the proximity tag the following message is displayed TAG NOT D...

Страница 36: ...low Me and press 3 Select the Follow Me index number you want to define and press 4 The display will show Destination Press 5 Enter the phone number including the area code if required or email address To enter an email address use the and keys to obtain the required characters and use the and keys to move to the required character position in the address Note If required when defining a telephone...

Страница 37: ... zone s as follows 1 Enter your user code followed by 2 Scroll down with the key to view all not ready zones The LCD only displays not ready zones that belong to the user code that was entered To change a zone s omit status 1 Press and enter your code followed by 2 Scroll to Activities and press 3 Select Omit and press 4 Select Zones and press 5 For omitting a zone only for the next system setting...

Страница 38: ...ling Tables to define your date Automatic Setting Unsetting 1 Press and enter your code followed by 2 Using the arrow keys scroll to the option Clock and press 3 Using the arrow keys scroll to the Scheduler option and press 4 Using the arrow keys scroll to the Weekly option and press 5 Select the Schedule program index number 6 Select Set Unset and press 7 Follow the LCD display messages that will...

Страница 39: ...uring the vacation according to the time schedule defined in the next step vacation definition User Limitation Program A user limitation program automatically prevents certain users from unsettting the system during specified time intervals By default all users of the system operate without this limitation When defining a user limitation program you need to define the following three parameters Us...

Страница 40: ...stroke sequence These keys will be entered in the form of characters in step 5 below of the procedure for programming the macro key For example to set partitions 1 and 2 in a 3 partitioned system you would press the following keys in step 5 Code This example requires the following sequence of characters 1234r12r To program a Macro 1 Press and enter your code followed by 2 Using the arrow keys scro...

Страница 41: ...he security applications of the system Each keyfob had a dedicated button to support each output The grand master or the engineer can control the management of these keyfobs Notes The following procedures are relevant only for stand alone keyfobs The keyfobs that control the security system can be defined and programmed only by your engineer Your engineer must define the outputs and the way they w...

Страница 42: ...e See Assign New Keyfob 2 Using the arrow keys scroll to the Delete All Keyfobs option and press 3 Use the key to toggle to Y and press Change keyfob buttons that controls the outputs By default button 3 small round key of the keyfob controls output 1 and button 4 egg shape controls output 2 This can be changed for all the keyfobs that are already assigned to the wireless receiver 1 Follow steps 1...

Страница 43: ...an intrusion zone s Omit Recall Recalls the most recent zone omit s Permanent Omit Omits and resets omitting any of the system s intrusion zones permanently This feature is different from regular zone omitting While in regular omitting the zone returns to be Not Omitted after it is set in permanent omit the zone remains omitted until its status is changed Tamper omit Provides the ability to omit b...

Страница 44: ...de must be entered Entering the code supplied by the engineer at this location will restore the system to the normal operation mode Configure SW Enable CS Each time this function is enabled your alarm company may subsequently gain a single remote access to your system to make any required programming changes CS connect Initiate Call Enables to establish communication between your system and your a...

Страница 45: ...s resetting and readying them for subsequent alarms Void Report Programming Some protocols have a report code to the alarm receiving centre for entering and exiting the installer engineer programming To avoid the entering report and save time this function postpones the report for two minutes during which the engineer can enter the programming menu and no report will be made Service Mode Used duri...

Страница 46: ...age 10 Alarm Memory Displays the five most recent alarm conditions stored by the system Partition Status Displays the partitions status the faults in the system and all not ready zones Pressing on the key from the normal operation mode displays the status of the partition to which the keypad is assigned Pressing the sequence CODE from the normal operation mode displays the status of all the partit...

Страница 47: ...es a proximity tag of the selected user Edit Label Assigns labels to users 16 characters long These labels are presented in the event log Delete By Tag Use this option to delete a proximity tag when the user of the tag is unknown Clock Time Date Allows the setting of the system time and dates as described on page 35 This definition is required for setting the scheduler programming in the system Sc...

Страница 48: ...ive minutes of walk test mode the keypad used to perform the walk test will indicate that the walk test period is about to end Full walk test The test displays the detected zones and type of detection Quick walk test The test displays the undetected zones Keypad test Momentarily tests the keypad indicators Sounder test Activates the squawk sound in the selected sounder Strobe test Activates the st...

Страница 49: ...ailed either form panel or the optional power supply module s Contact your dealer False Code Fault If enabled by your dealer your system will report a false code as a fault Once the fault has been displayed LCD keypad only it will automatically be removed from the system Phone Line Failure The telephone line used for alarm receiving centre communication is either disconnected or inoperative If all...

Страница 50: ...r programming the LightSYS2 and by the user for operating the system and viewing system status Event Log A list of system events can be displayed on an LCD keypad or uploaded to the alarm receiving centre via the configuration software and printed for further analysis Exit Entry Delay Your security system must incorporate an entry exit delay to allow proper entry and exit to and from the premises ...

Страница 51: ...hold appliance or premises lighting under the control of the LightSYS2 where it can be conveniently turned on and off automatically or by user command from any system keypad Weekly Schedules Through the use of the system s built in clock it is possible to schedule automatic operations such as setting and unsetting PO activation and user limitation Zone A single detector or collection of detectors ...

Страница 52: ...art Group Select Group A B C D Utility Output 1st PO No _________ 3rd PO No _________ 2nd PO No ________ 4th PO No _________ Note For the PO weekly schedule you can define a separate time definition during vacation User Access Authorization User Name User Name Note You can choose any user in the system Day Start Time 1 HH MM Stop Time 1 HH MM Start Time 2 HH MM Stop Time 2 HH MM Sunday Monday Tues...

Страница 53: ...mit a zone Code UNOM zone No 1234UNOM05 Activate Output Code POON PO No 1234POON1 Deactivate Output Code POOFF PO No 1234POOFF1 Change FM number Code FMPHONE FM serial number NEW New Phone No 1234FMPHONE 3 NEW0529692345 Get system status Code ST 1234ST Get last alarm Code AL 1234AL Get SIM credit level for prepaid cards Code CR 1234CR Notes SMS commands are not case sensitive they can contain both...

Страница 54: ...rform a Walk Test 1 Make sure the system is unset 2 Press and enter your code followed by 3 Using the arrow keys scroll to the option Maintenance and press 4 Select Walk Test and press 5 Select Full Walk test and press 6 A beep is heard and the following display appears MAKE WALK TEST AND HIT ANY KEY Walk throughout the protected area and make sure you test every zone in the system You have 60 min...

Страница 55: ...Page 55 NOTES ...

Страница 56: ... users of the system No part of its contents may be used for any other purpose disclosed to any person or firm or reproduced by any means electronic or mechanical without the express prior written permission of RISCO Group The information contained herein is for the purpose of illustration and reference only Information in this document is subject to change without notice Corporate and individual ...

Страница 57: ...O during the Warranty Period RISCO shall accept return of the defective Product in accordance with the below RMA procedure and at its option either i repair or have repaired the defective Product or ii provide a replacement product to the customer Return Material Authorization In the event that you need to return your Product for repair or replacement RISCO will provide you with a Return Merchandi...

Страница 58: ...erefore not responsible for and cannot guarantee the performance of the end user s security system which uses the Product or which the Product is a component of This Limited Warranty applies only to Products manufactured by or for RISCO Further this Limited Warranty does not apply to any software including operating system added to or provided with the Products or any third party software even if ...

Страница 59: ...ED THROUGH THE PRODUCT SHALL REMAIN SECURED OR NON DAMAGED CUSTOMER ACKNOWLEDGES THAT NEITHER RISCO NOR ITS LICENSORS CONTROL THE TRANSFER OF DATA OVER COMMUNICATIONS FACILITIES INCLUDING THE INTERNET GSM OR OTHER MEANS OF COMMUNICATIONS AND THAT RISCO S PRODUCTS MAY BE SUBJECT TO LIMITATIONS DELAYS AND OTHER PROBLEMS INHERENT IN THE USE OF SUCH MEANS OF COMMUNICATIONS RISCO IS NOT RESPONSIBLE FOR...

Страница 60: ...2 66590054 E mail support it riscogroup com China Shanghai Tel 86 21 52 39 0066 E mail support cn riscogroup com Spain Tel 34 91 490 2133 E mail support es riscogroup com Israel Tel 972 3 963 7777 E mail support riscogroup com France Tel 33 164 73 28 50 E mail support fr riscogroup com Australia Tel 1 800 991 542 E mail support au riscogroup com Belgium Benelux Tel 32 2522 7622 E mail support be r...

Отзывы: