background image

Issue 3

Royale - Freestanding ETR

- 12 -

Issue 3 - ©Rinnai

Before installing this product, please read this manual carefully.

Unpack the heater and check for damage. 

DO NOT INSTALL DAMAGED HEATER. 

If the

heater is damaged, contact your supplier for advice. Before installing the heater, check the
label for the correct gas type (see rating plate, bottom right hand side on the back of the unit).
Refer to local gas authority for confirmation of the gas type if you are in doubt.

Included in the carton

Customer Operation/Installation Manual, ceramic log set and granules.

IMPORTANT

1. This heater is not designed to be inbuilt.

2. This heater is not designed for use with Flexible Flueing.

.

3. The appliance must be installed in accordance with the local gas and electrical 

authority regulations.

4. For information on gas consumption, see data plate on the appliance.

5. Ensure that the area in which the appliance is installed has adequate fixed 

ventilation, this fixed ventilation must be provided as detailed in AS/NZS 5601.

6. This appliance must not be installed where curtains or other combustible materials 

could come into contact with it. In some cases curtains may need restraining.

7. This appliance is not designed to be built directly into a combustible opening.

8. Appliance must not be located below a power socket-outlet.

9. The local gas and electrical authorities will be able to advise on local regulations.

10.Rinnai appliance warranty conditions will be voided if non Rinnai flue components 

are fitted. Rinnai appliances are NOT CERTIFIED for use with non Rinnai flueing 
components.

11.The heater may emit smoke for approx. 2 hours when first operated. This is part of 

the burning in process and normal. Ensure adequate ventilation during this period.

12.The guard is fitted to this appliance to reduce the risk of fire or injury from burns 

and no part of it should be permanently removed. For protection of young children 
or the infirm, a secondary guard is recommended. Refer to AS4553.

INSTALLER INFORMATION - IMPORTANT POINTS

Содержание Royale FS35 ETR

Страница 1: ...on code AS NZS 5601 Gas Installations Any other local relevant Statutory Regulation Installation Service must be performed by an authorised person This heater is NOT designed to be inbuilt This heater...

Страница 2: ...ER INFORMATION SETTING THE CLOCK 4 OPERATING THE TIMERS 5 CUSTOMER INFORMATION SAFETY POINTS 6 CUSTOMER INFORMATION TROUBLE SHOOTING 10 CUSTOMER INFORMATION ERROR CODES 11 INSTALLER INFORMATION IMPORT...

Страница 3: ...g ON OFF TIME TEMP Display Shows either the time of day temperatures or coded error messages CLOCK ADJUSTMENT AND TIMER INDICATORS Indicates that clock or dual timer programme is being set OVERRIDE Te...

Страница 4: ...ental operation as well as small children from altering the controls To operate the lock simply press the LOCK button The function is activated immediately and the LOCK indicator will glow To Deactiva...

Страница 5: ...works within 5 metres and at an angle of 40 to the receiver which is located on the lower front edge of the heater Only use the battery type specified CR2032 Remove the battery if control is not going...

Страница 6: ...mming the ON OFF Timers Before programming the Timers you must ensure that the clock has been set to the correct time As an example let s program Timer 1 to heat the room by 7 10 am and finish at 9 00...

Страница 7: ...Forget Operation Your heater can be operated to alternate between Timers automatically during cold weather by selecting Timer 1 and Timer 2 together Both Timer indicators will glow The appliance will...

Страница 8: ...es must be maintained Do not restrict the warm air discharge by placing articles in front of the heater Do not spray aerosols whilst the heater is operating Most aerosols contain butane gas which can...

Страница 9: ...ble materials to come into contact with the heater This appliance must not be used for any purpose other than heating Do not allow anyone to post articles through the louvres Do not allow young childr...

Страница 10: ...o not allow anyone to sit on or lean against the appliance Do not unplug the heater while it is in operation or while the fans are still cycling Do not turn the heater off by unplugging it from the wa...

Страница 11: ...t should be permanently removed For protection of children or the infirm a secondary guard is recommended DO NOT CONNECT TO AN LPG GAS CYLINDER INDOORS DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIAN...

Страница 12: ...urned on Ensure gas supply is turned on Re ignite when power has been restored Repeat lighting procedure refer page 2 Smell of gas Leaking gas Turn off gas at meter and call installer Fan not working...

Страница 13: ...ON again If the Error Message still remains or returns on the next operation please contact your nearest service contact and arrange for a service call Error Code Probable Cause Comments Ignition Fail...

Страница 14: ...s adequate fixed ventilation this fixed ventilation must be provided as detailed in AS NZS 5601 6 This appliance must not be installed where curtains or other combustible materials could come into con...

Страница 15: ...where curtains or other combustible materials could come into contact with it In some cases curtains may need restraining See below for minimum clearances required 5 This heater is not designed to be...

Страница 16: ...Royale Freestanding ETR 14 Issue 3 Rinnai...

Страница 17: ...Use FLFKIT05 FLFTWKIT minimum of 3 metres of flue to be installed Rinnai appliance warranty conditions will be voided if non Rinnai flue components are fitted Rinnai appliances are NOT CERTIFIED for u...

Страница 18: ...Royale Freestanding ETR 15 Issue 3 Rinnai INSTALLERS INFORMATION DIMENSIONS...

Страница 19: ...s Supply Secure the heater 1 Secure the heater to the floor with 2 suitable fixings through the holes located on the rear of the base plate 2 Attach gas supply Note to the supplied fitting union All f...

Страница 20: ...rial in front of the Front Log Do not pour as dust particles from the plastic bag as it may block the burner ports Level it with a pencil or screw driver and remove excess material Note The ember bed...

Страница 21: ...ing on Page 9 before contacting your local service contacts listed on the back page of this booklet It may take approximately 2 hours of operation for the logs to achieve their full flame pattern and...

Страница 22: ...VER TRANSFORMER 6 5 4 1 1 3 ROOM TEMP THERMISTER XLP 04V XMP 03V OVER HEAT THERMISTER BK 2 3 REMOTE UNIT 10P 8P 917694 1 917692 1 YLR 03V BR BL BK BK BL BL R BK R R BL BL 1 1 10 8 10KR 8M Y SV3 SV2 SV...

Страница 23: ...lly aware of operating procedure Company name ____________________________________________________ Installers name ____________________________________________________ Address ________________________...

Страница 24: ...om mobile or public phones Australia Pty Ltd ABN 74 005 138 769 Internet www rinnai com au E mail enquiry rinnai com au Internet www rinnai co nz E mail sales rinnai co nz Head Office New Zealand 691...

Отзывы: