Issue 3
Royale - Freestanding ETR
- 18 -
Issue 3 - ©Rinnai
1. To check burner pressure
• Turn OFF and disconnect the 240V power
supply connection.
• Turn ON Gas supply.
• Refer to Data Plate or the Technical
Specification section in this manual for
burner pressures.
• Open right hand side front cover panel
(Remove 1-screw located under the front
of the panel).
• Remove 240V electrical cover.
• Remove test point screw and attach
manometer to test point, the test point is
on the lower right hand side of the valve
assembly.
• Connect the 240V power supply.
Caution
with the electrical panel open 240V
terminals will be exposed.
• Light heater, turn to High heat setting, wait
8 minutes and check pressure.
• If adjustments are necessary, the
regulator is situated on the lower right
hand corner and should be set to the
pressures on the data-plate.
• Disconnect the 240V power supply.
• Remove manometer and replace test
point screw, check for gas escapes at test
point screw.
• Replace electrical cover and secure side
panel.
• Reconnect the power supply.
• Turn the heater on and off a few times to
check ignition.
• All burner aerations are factory preset and
cannot be adjusted.
• If you are unable to get the unit to operate
correctly, refer to Trouble Shooting on
Page 9 before contacting your local
service contacts listed on the back page
of this booklet.
• It may take approximately 2 hours of
operation for the logs to achieve their full
flame pattern and glow.
It is the responsibility of the installer to
check that under normal operating
conditions of the appliance, all flue gases
are exhausted to the outside atmosphere
and that there is no spillage of
combustion gases into the room. Refer to
AS/NZS 5601.
2. Commissioning
Installation and Commissioning
Checklist
Complete the Installation Checklist and the
Installer details on page 20 and make sure
that this instruction book is left with the
customer.
Instruct Customer
Make sure the customer understands the
instructions and the operation of the
appliance.
Advise that :
• The guard on this appliance conforms
to A.G.A. requirements. It is designed
to prevent the risk of injury from burns
and no part of it should be permanently
removed. IT DOES NOT GIVE FULL
PROTECTION TO YOUNG CHILDREN
OR THE INFIRM.
• For protection of young children or the
infirm, a secondary guard is
recommended.
• This appliance is designed to operate
with luminous flames and may exhibit
slight carbon deposits.
• During the initial burning in period,
(approx. 2 hours) some smoke and
smell may be experienced during this
period, the heater should be run on the
High position in a well ventilated room.
INSTALLERS INFORMATION - TESTING & COMMISSIONING