
Issue 3
Royale - Freestanding ETR
- 16 -
Issue 3 - ©Rinnai
Available Flueing Options as follows:
1. Position heater taking into consideration the Information under “Location”.
2. Assemble and connect flue in accordance with the Rinnai Flueing Installation manual for
Rinnai Flame Fire heaters.
3. For pipe sizing, refer to your local gas installation
codes. Copper supply should be run leaving a 1/2”
flared connection at the position shown.
4. Run Gas Supply.
Secure the heater
1. Secure the heater to the floor with 2 suitable
fixings through the holes located on the rear of the
base plate.
2. Attach gas supply Note: to the supplied fitting
union.
All foreign materials such as fillings must be purged from the gas supply, before
connection damage as they may damage the gas controls.
NOTE: On completion of work a gas leak test must
be carried out.
Use a soapy solution on all gas connections.
Leaks will be visible when the soapy solution
forms bubbles.
When finished, wipe soapy solution with a rag to
remove residue.
HEATER
HEATER
OBSTRUCTION
A
B
C
HEATER
INSTALLERS INFORMATION - FLUEING