SAFETY

IMPORTANT

DO NOT

 sit or lean against the heater.

DO NOT

 allow children or elderly persons to sleep in the warm air discharge from the heater.

DO NOT

 post or allow children to post articles into the louvres of the heater.

DO NOT

 cover or place articles on this heater.

DO NOT

 place articles in front of the louvres.

DO NOT

 operate / install this heater in areas where painting is taking place, or in places such as 

hairdressing salons, where there may be fluff and dust, and where aerosols are used.

DO NOT

 place articles on or against this appliance.

DO NOT

 use or store flammable materials near this appliance. Keep flammable materials away from 

heater.
Combustible materials 

MUST NOT 

be placed where the heater could ignite them.

DO NOT

 spray aerosols in the vicinity of this appliance while it is in operation. Most aerosols contain 

flammable substances which can be a hazard if used near this appliance when it is in use.

DO NOT

 use power boards or double adaptors to operate this appliance. The heater MUST NOT be 

located below a power socket-outlet.

DO NOT

 place containers of liquid on top of the heater. Water spillage can cause extensive damage 

to the appliance and create an electrocution hazard. 

DO NOT CONNECT TO AN LPG GAS CYLINDER INDOORS.

Turn the heater ‘OFF’ when not in use.

DO NOT 

unplug the heater while it is in operation or while the fan is still cycling.

When the heater is operated for the first time or after long periods of non use a slight odour may be 

emitted, this is normal. However if odours persist switch ‘OFF’ the appliance and contact Rinnai.

Appliances incorporating a live fuel effect and designed to operate with luminous flames, may exhibit 

slight carbon deposits.
This is primarily a decorative appliance and has not been designed as a space heater.

NOT INTENDED FOR FIREPLACE INSERT

WHAT TO DO IF YOU SMELL GAS
DO NOT 

try to light any appliances.

DO NOT

 touch any electrical switches: do not use any phone in your building

Immediately close the shut-off valve at the gas meter or bottles
Call an authorised service technician

SAFETY DEVICES

Electrical Fuse: 

The electrical circuits are protected by a fuse.

Flame Failure Sensing System: 

This device automatically cuts off the gas supply to the heater in the event of a flame failure.

Power Failure: 

In the event of a power failure or power cut, the gas valves will automatically close.

Содержание RF1200TW

Страница 1: ...Municipal Building Codes including local OH S requirements This appliance must be installed maintained and removed by an Authorised Person For continued safety of this appliance it must be installed...

Страница 2: ...Effect appliance We trust you will have many years of enjoyment from your purchase THIS MANUAL CONTAINS IMPORTANT INFORMATION FOR SAFETY PLEASE READ CAREFULLY BEFORE PROCEEDING WITH ASSEMBLY INSTALLA...

Страница 3: ...fety Devices 4 Features 5 Control Panel Operation 5 Remote Control Operation 6 Operational Safety 6 Burner Media 7 Power Failure 7 Cleaning 7 When to call for Service 7 Service 7 Installation Table of...

Страница 4: ...ed in separate cartons the following table lists which components are in each carton Ensure that the components listed for the installation method being installed are present before proceeding with th...

Страница 5: ...air in the room contains contaminants like cooking vapours or cigarette smoke To avoid this possibility it is recommended that a mat or similar protective sheet be placed in front of the appliance ext...

Страница 6: ...ntainers of liquid on top of the heater Water spillage can cause extensive damage to the appliance and create an electrocution hazard DO NOT CONNECT TO AN LPG GAS CYLINDER INDOORS Turn the heater OFF...

Страница 7: ...sure a quick warming up of the firebox and flue NOTE The appliance will start on the same flame setting it was last used at unless the mains power supply has been disrupted or disconnected whereby the...

Страница 8: ...ppliance can be set whilst in operation for a 30 minute delayed switch off The red indicator light on the front panel of the appliance will flash when this mode has been activated Pressing the auto ti...

Страница 9: ...firebox this can cause the paint to blister and possibly damage the appliance If you can smell gas regardless of whether the appliance is going or not NOTE There can be a brief smell of gas as the app...

Страница 10: ...Rinnai 8 RF1200TW OIM This page is intentionally blank...

Страница 11: ...s Hearths 13 Ventilation 14 Flue Requirements 14 Engine Installation 16 External Wall Installation 18 Appliance Gas Connection Commissioning 20 Aeration Sleeve Details 21 Pilot Burner Performance 22 T...

Страница 12: ...CE INSERT Only the approved flue componenets specified by Rinnai MUST BE used This appliance must be installed into a well ventilated room in accordance with AS NZS 5601 This appliance is designed for...

Страница 13: ...ame Monitoring Flame rod Control Electronic control with IR remote control NOTE For all other specifications refer to the appliance data plate External Glass This appliance is able to be installed as...

Страница 14: ...to connect the appliance to the consumer piping Electrical Supply The appliance is supplied with a power lead approx 1 8m long This needs to be connected to an isolating wall socket within the cavity...

Страница 15: ...ot limited to ornaments such as Paintings Prints Photographs Tapestries Mirrors Stuffed Animals etc IDEA Use either a shelf or mantle below the TV or ornament or alternately you can construct a recess...

Страница 16: ...irect FRONT VIEW FRONT VIEW A A A A 474mm E A A A A Twin Extended Offset Twin Offset A A SIDE VIEW SIDE VIEW G G A E E E SIDE VIEW SIDE VIEW B Y Piece Offset A E E Y Piece Extended Offset C C E A E C...

Страница 17: ...OWL200 250 Connection 200mm Outer 350mm Y Piece Collector Box Assembly 1 Fit the AUFLUE200 250 flue pipes A onto the engine using rivets and sealant as required 2 Fit the 200mm inner 45 bends B2 but d...

Страница 18: ...mm stainless steel inner 300mm galvanised outer flue Note the Y piece does not have to be used and the flue can be finished using two 200 250 flue Fire is viewed from the open side with the glass to t...

Страница 19: ...er flue While the Y Piece can be fitted directly onto the engine it is recommended that 1200mm of flue is fitted before the Y piece Y Piece refer to Notes on Fluing in the Installation Guide for more...

Страница 20: ...no concern about blocking the side of the appliance IMPORTANT It is important that the glass is sealed against the appliance to prevent hot air flowing up into any combustible materials used directly...

Страница 21: ...been removed from the stainless steel louvre and all dust and fingerprints etc are removed before fixing outer glass to engine whilst removal of the inner glass is possible there is no access to the t...

Страница 22: ...d flaring the gas supply pipe purge the gas pipe and fix the gas control assembly back in place and connect the gas 8 Replace and fix the burner assembly in place Gas Commissioning WARNING 240 VOLTS R...

Страница 23: ...eration 9 During the initial burn in period some smoke and smell may be emitted The appliance should be run on the high position in a well ventilated room until these dissipate 10 Check the flame patt...

Страница 24: ...tive cardboard cover taped to the front of the engine using a low tack tape to prevent plaster dust and debris from entering the engine and damaging the paint work 1 Fit the Minimal Trim so that the t...

Страница 25: ...ouring the media over the burner as this can block the burner ports with the fine dust that tends to settle in the bottom of the bags during shipping 4 Place all the remaining coals and logs on top of...

Страница 26: ...change gas cylinder Sparking continues after pilot flame ignites Faulty flame rod Service Call Dirty gas in cylinder LPG Propane Replace or change over gas cylinder Pilot ignites yet main flame does...