GAS & ELECTRICAL SUPPLIES
Gas Supply
A suitable gas supply needs to be provided to the left hand rear corner of the installation cavity prior to installing
the appliance The pipe sizing should be calculated to supply at least 67MJ/h
Allow sufficient pipe to make the connection
as shown right.
NOTE
The gas inlet access point for
this appliance is provided with
a set folding flaps to allow
piping with fittings attached
to be passed through for
connection.
For vermin control ensure that
these flaps are closed again
once the piping has been
installed.
Use the supplied gas connection kit (200mm
3/8 Flexi tube with plug and 3/8” - 1/2”
reducing flare connector) to connect the
appliance to the consumer piping.
Electrical Supply
The appliance is supplied with a power
lead approx. 1.8m long. This needs to be
connected to an isolating wall socket within
the cavity and connected to an isolating wall
switch, preferably located to the right of the
appliance, facing into the room, not inside
the framing cavity.
This supply is used to isolate all power from
appliance. The power cord is designed for a
230/240V AC 10 amp supply.
Electrical connections must be in accordance
with AS/NZS 3000 and installed by an
authorised person.
CLEARANCES
The appliance must be installed with the shown
minimum clearances to combustible materials.
See also “Mantles, Surrounds, Recesses
& Hearths” on page 13 for additional
information.
* From finished wall lining
234*
103
19
272*
308
Approx
524
Approx
Open Side
Glass Side
A
B
A
B
A
A
300mm Min
1000mm Min
750mm