Rinnai
6
RF1200TW OIM
REMOTE CONTROL OPERATION
NOTE
Here are a few things you should know about your remote control to keep it working at its best:
•
The remote uses 4 AAA batteries, and has a range of about 8 metres with fresh batteries.
•
When replacing the batteries, replace all 4, DO NOT mix old with new.
•
Remove the batteries if the appliance is not going to be used for extended periods.
•
Some fluorescent lights can affect the performance of the remote.
•
Avoid dropping the remote or getting it wet
.
Ignition
Point the remote control towards the appliance and press the power button for at least 1 second. The appliance
will then commence the ignition sequence.
Always run the appliance on high for at least a few minutes to ensure a quick warming up of the firebox and flue.
The flame can then be turned down if so desired.
NOTE
The appliance will start on the same flame setting it was last used at unless the mains power
supply has been disrupted or disconnected, whereby the default flame setting is reset to low. To
ensure a high setting, during ignition press the flame c button for up to 10 seconds.
Flame Control
Press the flame c button to increase the fame or the flame control -
button to decrease the flame.
Fan Control
The appliance has a two speed fan (outlet on open side of appliance). Press
the fan c or - buttons to switch the fan to High, Low or Off.
Turning Off
To switch the appliance off, press the power button on the remote control.
Auto Off Timer
By pressing the auto off timer button on the remote control the appliance can
be set whilst in operation for a 30 minute delayed switch off. The red indicator
light on the front panel of the appliance will flash when this mode has been
activated. Pressing the auto timer button a second time will cancel this mode.
OPERATIONAL SAFETY
This appliance is factory tested and the installation MUST BE tested by an authorised installer. You should not
experience any odour from your appliance other than initial burn off smell the first time it is used. Should any odour
persist after the initial burn in, turn off the gas supply and arrange for an authorised person to make a service call.
This appliance has a flame failure safety system which ensures that in the event of an ignition failure, gas supply
failure or flame being extinguished for any reason, the appliance will shut down. The appliance will attempt to re-
start automatically.
LOCK OUT
If the appliance fails to re-ignite then the appliance will “lock out” and will need to be re-set manually by pressing
the ON/OFF button twice to re-set and re-start the ignition sequence.
Wait at least 10 seconds before re-starting the appliance and if the appliance fails to ignite after 3 attempts then
turn off the power and refer to the trouble shooting section on page 24.
NOTE
This appliance burns with a real flame and as such there are considerations to be made to ensure
the safety of children and the infirm. In such circumstances a fire guard should be secured in front
of the appliance. Furniture and other objects must not be placed within 1 metre of the fireplace.
Make sure that the lower and upper air inlets are not blocked as this could cause damage to the
fan or cause the gas controls to overheat.
Power
Flame
Control
Fan
Control
Auto Off/