Read these rules and the instructions
carefully.  Check all local codes.  Failure
to follow these could cause a malfunction
of the heater resulting in death, serious
bodily injury and/or property damage.

8

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.

9

WARNING:  Any change to this heater
or its controls can be dangerous.

10 If a gas leak is suspected, turn heater

off, turn gas supply valve off at appliance
connector valve.  Open windows to
ventilate area immediately and contact
your dealer or gas company.

11 DO NOT PLACE CLOTHING OR

FLAMMABLE MATERIALS,
GASOLINE AND OTHER FLAMMABLE
VAPORS AND LIQUIDS, ON OR NEAR
THE HEATER.

12 Do not spray aerosols when the heater

is in operation.

13 YOUNG CHILDREN SHOULD BE

CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM WITH
THE HEATER.

14 LPG containers must not be installed

indoors.

15 Do not use this appliance if any part has

been under water.  Immediately call a

Unpack the heater and check for damage (DO NOT INSTALL DAMAGED HEATER).  If  the
heater is damaged, contact your supplier for advice. Before installing the heater, check the
label for the correct gas type (see rating plate,  bottom right hand side of pillar).  Refer to local
gas authority for confirmation of the gas type if you are in doubt.

Included in the carton

Customer operation information.

IMPORTANT

Before using this product, please read this manual carefully to ensure proper use of the product:

1

The installation must conform with local
codes, or in the absence of local codes,
the National Fuel Gas Code, ANSI
Z223.1, or the Canadian Installation
Code, CAN/CGA -B149.

2

For information on gas type see the data
plate on the heater.

3

This heater must not be installed where
curtains or other combustible materials
could come into contact with it.  In some
cases curtains may need restraining.

4

If you move, check the gas type in the
area where you are moving to.  The local
gas authority will be able to advise on
local regulations.

5

This heater discharges a large volume
of warm air to provide even heat
distribution.  If the air in the room
contains cooking vapor or cigarette
smoke, and the heater is used on a
carpet, the surface of the carpet may
become discolored.  In addition, some
nylon carpets contain dyes which may be
affected by the warm air flow.  Some soft
vinyl surfaces are also subject to
distortion, or discoloration by warm air.
To prevent discoloration of carpets, etc.,
a mat should be placed in front of the
appliance, extending about 30” in front
of it.

6

This heater must be installed on a hearth
at least 2” thick and the width and depth
of the heater.

IMPORTANT POINTS / USAGE AND INSTALLATION MUSTS

Содержание IB35ETRLC

Страница 1: ...upplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance is only for use with the type of gas indicated on...

Страница 2: ...the Warranty For the name of the Authorized Distributor or Installer nearest you please contact your local HVAC dealer or gas service technician visit the Rinnai website www rinnai us call Rinnai at...

Страница 3: ...your safety read before operating heater 8 Control panel layout 9 Operation 9 Location 13 Venting 15 Gas connection 15 Log installation 16 Testing and commissioning 17 Maintenance instructions 18 Wiri...

Страница 4: ...er with forced convection and natural draft flue system Gas Control Electronic control valve Burners Ember bed flame and heat burner Warm Air Discharge Top front louvres Flue Natural draft Approved 4...

Страница 5: ...Refer to local gas authority for confirmation of the gas type if you are in doubt Included in the carton Customer operation information IMPORTANT Before using this product please read this manual care...

Страница 6: ...nst the appliance 30 DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITUREAND DRAPERIES 31 CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE...

Страница 7: ...Flue Termination Fan Combustion System Ignition System Operation Temperature control Electronic thermostat High Low Off Flame picture select option Up Down buttons Temperature range Low 50 F 60 F 80 F...

Страница 8: ...uctions If you cannot reach your gas supplier call the fire dept C Use only your hand to push the gas control buttons Never use tools If the buttons will not activate by hand don t try and repair it c...

Страница 9: ...ss the ON OFF button OFF then ON again TURNING OFF Simply press the ON OFF button to switch off the unit The ON indicator will go out The convection fan will continue to operate for several minutes af...

Страница 10: ...hen the correct hour shows on the Digital Display Confirm that you have selected AM or PM as required a small indicator on the left hand side of the Digital Display indicates the AM PM setting Use the...

Страница 11: ...failure the system memory will retain the Timer programs and the clock will stop at the time the power goes off The clock will start again when the power comes back on but the time will be slow by th...

Страница 12: ...f the remote control The clip is removed by inserting a coin or similar into the recess in the back of the remote control and sliding downwards The battery must be of type CR 2032 and will only operat...

Страница 13: ...at room ventilation complies with local regulations 7 This heater must be mounted on a hearth not less than 2 thick and at least the width and depth of the heater 8 Installation location shall provide...

Страница 14: ...ns a zero clearance kit must be used Combustible installation This may require a sheet of non combustible material to be laid under the heater or a layer of cement to be poured on the hearth The firep...

Страница 15: ...be installed vertically only If installation prevents this then there must be at least 4 feet of vertical flue before any bends The flue must not fall below horizontal at any stage There must not be m...

Страница 16: ...remove the cover A hole is provided on the right hand side of the junction box for a suitable electrical gland to be attached and the electrical supply to pass through 6 There are two wires one black...

Страница 17: ...ewdriver and remove excess material Note The ember bed material must be placed after the logs are fitted If the logs are to be removed for any reason the ember bed material must be removed first and r...

Страница 18: ...3 It may take approximately 2 hours for the logs to achieve their full flame pattern and glow During the initial burning in period some smoke and smell may be experienced The heater should be run on t...

Страница 19: ...polishes to clean the casing while the fire is in operation Do not damage or distort any part of the heater Do not use wet cloth or spray cleaners on burners VENT MAINTENANCE The flue should be inspec...

Страница 20: ...not to damage the fiber seal on the perimeter of the glass 4 The glass may be cleaned with a damp sponge and soapy water If the seal is damaged it should be replaced Remove any soot deposit from the l...

Страница 21: ...21 WIRING DIAGRAM PCB LAYOUT Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing...

Страница 22: ...g up Small soot deposit Normal operation No action required Inadequate fluesystem Log misalignment Call service department agent Incorrect gas pressure Condensationon glass Normal operation Allow fire...

Страница 23: ...block Service call Power failure Service call Room temperature sensor faulty ERROR CODES ERROR CODE MESSAGE The Flame Fire ETR has the ability to check its own operation continuously If a fault occur...

Страница 24: ...24 EXPLODED DIAGRAMS...

Страница 25: ...25...

Страница 26: ...AME 23 2 7875 ELECTRODE 23 2 7520 THERMOCOUPLE 24 2 7876 ELECTRODE NUT S I T 25 2 7872 INJECTOR NG 51 NG 2 7873 INJECTOR LPG 31 LP 27 2 7900 ELECTRODE NUT ETR 28 2 7902 SPACER ELECTRODE PILOT 29 2 798...

Страница 27: ...N PANEL IBR ETR US 76 1 7601 1 FAN GUIDE TOP NAT IB35ETR 77 1 7613 FAN DIVIDING BRKT RH IB35ETR 78 2 7554 CLIP THERMISTER CP 90125 2 B 79 1 7989 REAR PANEL IBR USA 80 1 7197 REAR TOP PANEL IBR 81 1 71...

Страница 28: ...28 INSTALLATION NOTES...

Страница 29: ...29 INSTALLATION NOTES...

Страница 30: ...30 INSTALLATION NOTES...

Страница 31: ...__________________________ Date ___________________ INSTALLATION COMMISSIONING CHECKLIST INSTALLER DETAILS 1 Was a fireplace inspection carried out i e clearances combustibles etc 2 Was a manufactured...

Страница 32: ...Part Number 7919B zx...

Отзывы: