Rinnai IB35ETRLC Скачать руководство пользователя страница 27

 27

53

1

7920

FR ONT PILOT SH IELD U SA PAIN TED

54

1

5327G

BR AN D  BADGE GOLD

55

1

4993

GAS  C ONTR OL ASSY  N G  U S  IB35ETR

NG

1

4994

GAS C ONTR OL ASSY LP U S IB35ETR

LP

57

2

6308

O RING MA IN GA S

58

2

6313

GA S TUBE RETA INER

59

1

7536

RECEIV ER UNIT ETR-015X01

60

1

7537

RECEIV ER UNIT HOLDER 35ETR-016

61

1

7539

RECEIV ER COV ER 35ETR-017

62

1

7542

SPA RK IGNITOR ETR EI-145

63

1

7544

PCB A SSY  ETR 35ETR-020

64

1

7596

PCB MOUNTING BRKT PNT IB35ETR

65

1

7549

THERMISTOR OH SWIT.35ETR-023

66

1

7545

CONTROL UNIT A SSY  35ETR-010BX0

BLA CK

1

7545S

CONTROL UNIT 35ETR-010B SILV ER

SILV ER

67

1

7541

REMOTE CONTROL 556F-2005

68

1

7899

TRA NSF. USA  ETR ET-277 100V

69

2

7288

FA N MOUNTING BRA CKET IBR

70

1

7072

FA N MTG PA NEL IBR

71

1

7614

REGULA TOR SUPPORT IB35ETR

72

1

7202

FA N PA RTITION PA NEL LOWER IBR

73

1

7610

GA S MA NIFOLD MTG BRKT IB35ETR

74

1

7220

FA N DIV IDING PA NEL BRKT IB

75

1

7858

FA N PA RTITION PA NEL IBR ETR US

76

1

7601-1

FA N GUIDE TOP NA T IB35ETR

77

1

7613

FA N DIV IDING BRKT RH IB35ETR

78

2

7554

CLIP THERMISTER CP-90125-2-B

79

1

7989

REA R PA NEL IBR USA

80

1

7197

REA R TOP PA NEL IBR

81

1

7198

REA R SIDE PA NEL LH IBR

82

1

7563

BRA CKET THERMA L FUSE IB35ETR

83

1

7621

THERMISTER BRKT REA R IB35ETR

84

1

7190V

SURR TOP PA NEL IBR V IPER

BLA CK

1

7190SP

SURR TOP PA NEL PA INTED IBR SP

SILV ER

85

1

7191V

SURROUND LEFT HA ND IBR V IPER

BLA CK

1

7191SP

SURR LH PA INTED IBR SP

SILV ER

86

1

7192V

SURROUND RIGHT HA ND IBR V IPER

BLA CK

1

7192SP

SURR RH PA INTED IBR SP

SILV ER

87

4

7177

DOOR SPRING IBR

88

1

7193V

DOOR LH IBR V IPER

BLA CK

1

7193SP

DOOR LH PA INTED IBR SP

SILV ER

89

1

7194V

DOOR RH IBR V IPER

BLA CK

1

7194SP

DOOR RH PA INTED IBR SP

SILV ER

90

1

7227

A IR GUIDE TOP IBR

91

1

7228

FRONT TRIM PA INTED IBR

92

2

7598

CA BLE COV ER PA INTED IB35ETR

93

1

7615V

TOP PA NEL A SSY  IB35ETR V IPER

BLA CK

1

7615SP

TOP PA NEL A SSY  IB35ETR SP

SILV ER

94

1

7230

FA N DIV IDING PA NEL IBR

95

1

7617

PROTECTIV E SHIELD IB35ETR PNT

96

1

7857

FA N PA RTITION PA NL DGREA SE USA

97

1

7221

FA N DISCHA RGE GUIDE IBR

Содержание IB35ETRLC

Страница 1: ...upplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance is only for use with the type of gas indicated on...

Страница 2: ...the Warranty For the name of the Authorized Distributor or Installer nearest you please contact your local HVAC dealer or gas service technician visit the Rinnai website www rinnai us call Rinnai at...

Страница 3: ...your safety read before operating heater 8 Control panel layout 9 Operation 9 Location 13 Venting 15 Gas connection 15 Log installation 16 Testing and commissioning 17 Maintenance instructions 18 Wiri...

Страница 4: ...er with forced convection and natural draft flue system Gas Control Electronic control valve Burners Ember bed flame and heat burner Warm Air Discharge Top front louvres Flue Natural draft Approved 4...

Страница 5: ...Refer to local gas authority for confirmation of the gas type if you are in doubt Included in the carton Customer operation information IMPORTANT Before using this product please read this manual care...

Страница 6: ...nst the appliance 30 DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITUREAND DRAPERIES 31 CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE...

Страница 7: ...Flue Termination Fan Combustion System Ignition System Operation Temperature control Electronic thermostat High Low Off Flame picture select option Up Down buttons Temperature range Low 50 F 60 F 80 F...

Страница 8: ...uctions If you cannot reach your gas supplier call the fire dept C Use only your hand to push the gas control buttons Never use tools If the buttons will not activate by hand don t try and repair it c...

Страница 9: ...ss the ON OFF button OFF then ON again TURNING OFF Simply press the ON OFF button to switch off the unit The ON indicator will go out The convection fan will continue to operate for several minutes af...

Страница 10: ...hen the correct hour shows on the Digital Display Confirm that you have selected AM or PM as required a small indicator on the left hand side of the Digital Display indicates the AM PM setting Use the...

Страница 11: ...failure the system memory will retain the Timer programs and the clock will stop at the time the power goes off The clock will start again when the power comes back on but the time will be slow by th...

Страница 12: ...f the remote control The clip is removed by inserting a coin or similar into the recess in the back of the remote control and sliding downwards The battery must be of type CR 2032 and will only operat...

Страница 13: ...at room ventilation complies with local regulations 7 This heater must be mounted on a hearth not less than 2 thick and at least the width and depth of the heater 8 Installation location shall provide...

Страница 14: ...ns a zero clearance kit must be used Combustible installation This may require a sheet of non combustible material to be laid under the heater or a layer of cement to be poured on the hearth The firep...

Страница 15: ...be installed vertically only If installation prevents this then there must be at least 4 feet of vertical flue before any bends The flue must not fall below horizontal at any stage There must not be m...

Страница 16: ...remove the cover A hole is provided on the right hand side of the junction box for a suitable electrical gland to be attached and the electrical supply to pass through 6 There are two wires one black...

Страница 17: ...ewdriver and remove excess material Note The ember bed material must be placed after the logs are fitted If the logs are to be removed for any reason the ember bed material must be removed first and r...

Страница 18: ...3 It may take approximately 2 hours for the logs to achieve their full flame pattern and glow During the initial burning in period some smoke and smell may be experienced The heater should be run on t...

Страница 19: ...polishes to clean the casing while the fire is in operation Do not damage or distort any part of the heater Do not use wet cloth or spray cleaners on burners VENT MAINTENANCE The flue should be inspec...

Страница 20: ...not to damage the fiber seal on the perimeter of the glass 4 The glass may be cleaned with a damp sponge and soapy water If the seal is damaged it should be replaced Remove any soot deposit from the l...

Страница 21: ...21 WIRING DIAGRAM PCB LAYOUT Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing...

Страница 22: ...g up Small soot deposit Normal operation No action required Inadequate fluesystem Log misalignment Call service department agent Incorrect gas pressure Condensationon glass Normal operation Allow fire...

Страница 23: ...block Service call Power failure Service call Room temperature sensor faulty ERROR CODES ERROR CODE MESSAGE The Flame Fire ETR has the ability to check its own operation continuously If a fault occur...

Страница 24: ...24 EXPLODED DIAGRAMS...

Страница 25: ...25...

Страница 26: ...AME 23 2 7875 ELECTRODE 23 2 7520 THERMOCOUPLE 24 2 7876 ELECTRODE NUT S I T 25 2 7872 INJECTOR NG 51 NG 2 7873 INJECTOR LPG 31 LP 27 2 7900 ELECTRODE NUT ETR 28 2 7902 SPACER ELECTRODE PILOT 29 2 798...

Страница 27: ...N PANEL IBR ETR US 76 1 7601 1 FAN GUIDE TOP NAT IB35ETR 77 1 7613 FAN DIVIDING BRKT RH IB35ETR 78 2 7554 CLIP THERMISTER CP 90125 2 B 79 1 7989 REAR PANEL IBR USA 80 1 7197 REAR TOP PANEL IBR 81 1 71...

Страница 28: ...28 INSTALLATION NOTES...

Страница 29: ...29 INSTALLATION NOTES...

Страница 30: ...30 INSTALLATION NOTES...

Страница 31: ...__________________________ Date ___________________ INSTALLATION COMMISSIONING CHECKLIST INSTALLER DETAILS 1 Was a fireplace inspection carried out i e clearances combustibles etc 2 Was a manufactured...

Страница 32: ...Part Number 7919B zx...