background image

 26

PARTS LIST

ITEM NO.

QTY.

PART NO.

1

1

7993-1

FLUE SPIGOT ASSY NAT IB USA

2

1

7074

HEAT EXCHANGER FRONT ASSY 3+3H

3

1

7075

HEAT EXCHANGER REAR ASSY 3H

4

6

6624

BURNER EXCHANGER TRANSFER TUBE

5

2

6625

BURNER HEAT EXCHANGER BRACKET

6

1

7927

COMB CHAMB ASSY IB ETR USA PAI

7

1

7616V

FRONT PANEL IB35ETR VIPER

BLACK

1

7616SP

FRONT PANEL IB35ETR SP

SILVER

8

1

7141

FAN QLN65/0030-3038LH MVL 110V

9

9

7130

FAN MTG SLEEVE

10

9

7129

FAN MTG GROMMET

11

9

9028

SCREW 8X5/8 MUSH HEAD 33611923

12

3

6651

CUSHION RUBBER REH210

13

1

7950

INJECTOR BLOCK BRKT FRONT MKII

14

1

7951

INJECTOR BLOCK BRKT REAR MKII

15

1

7338

INJECTOR BRAY 260 CAT33 MULTI

NG

1

7175

INJECTOR BRAY 120 CAT23 SINGLE

LP

17

1

7337

INJECTOR BRAY 560 CAT33 MULTI

NG

1

7183

INJECTOR BRAY 200 CAT33 MULTI

LP

19

1

7906

INJECTOR BRAY 180 CAT23 SINGLE

NG

1

7173

INJECTOR BRAY 95 CAT23 SINGLE

LP

20

6

9064

SCREW M4 X 8 PHPMZ SPRINGWASH

21

2

7870

PILOT BODY TOP CONVERTIBLE

22

2

7871

PILOT CONVERTIBLE HOOD 2 FLAME

23

2

7875

ELECTRODE

23

2

7520

THERMOCOUPLE

24

2

7876

ELECTRODE NUT (S.I.T)

25

2

7872

INJECTOR NG 51

NG

2

7873

INJECTOR LPG 31

LP

27

2

7900

ELECTRODE NUT ETR

28

2

7902

SPACER ELECTRODE PILOT

29

2

7986

ELBOW 6mmx1/8"BSPT BFM690602

30

1

7904

PILOT BRACKET FRONT USA

31

1

7985

PILOT BRACKET REAR ETR USA

32

1

7931

GAS SUPPLY TUBE A IBETR

33

1

7932

GAS SUPPLY TUBE B IBETR

34

1

7933

GAS SUPPLY TUBE C IBETR

35

1

7945-1

TUBE IBETR FRONT CUT

36

1

7946-1

TUBE CUT IBETR REAR

37

3

7952

INJECTOR BLOCK A+B

38

1

7924

FRONT BURNER US ASSY PAINTED

39

1

4990

MAIN BURNER NG USA FLAME

NG

4990L

MAIN BURNER LP USA FLAME

LP

40

1

7044

CERAMIC LOG SET c/w GRANULES

41

1

6384

BURNER COSYPANEL

42

1

7276

BURNER BRACKET

43

1

7258

AERATION SLEEVE SHORT

44

2

7564

ELECTRODE SLEEVE

45

2

7240

LOG LOCATING SLEEVE

46

2

9115

SCREW M5 X 25 PHSMZ PHIL

47

7

7029

LOUVRE TUBE FS 9.5 GOLD

BLACK

7

7029BN

LOUVRE TUBE FS 9.5 BLK NICKEL

SILVER

48

1

7099

LOUVRE TUBE RD 15.8 GOLD

BLACK

1

7099BN

LOUVRE TUBE RD 15.8 BKL NICKLE

SILVER

49

1

4996

GLASS PANEL ASSY IB/FS35

50

1

7004

BURNER DIVERT PANEL PTD ETR

51

1

7033

GLASS RET TOP ASSY PAINTED

52

1

7037

GLASS RET BOTTOM ASSY PAINTED

DESCRIPTION

Содержание IB35ETRLC

Страница 1: ...upplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance is only for use with the type of gas indicated on...

Страница 2: ...the Warranty For the name of the Authorized Distributor or Installer nearest you please contact your local HVAC dealer or gas service technician visit the Rinnai website www rinnai us call Rinnai at...

Страница 3: ...your safety read before operating heater 8 Control panel layout 9 Operation 9 Location 13 Venting 15 Gas connection 15 Log installation 16 Testing and commissioning 17 Maintenance instructions 18 Wiri...

Страница 4: ...er with forced convection and natural draft flue system Gas Control Electronic control valve Burners Ember bed flame and heat burner Warm Air Discharge Top front louvres Flue Natural draft Approved 4...

Страница 5: ...Refer to local gas authority for confirmation of the gas type if you are in doubt Included in the carton Customer operation information IMPORTANT Before using this product please read this manual care...

Страница 6: ...nst the appliance 30 DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITUREAND DRAPERIES 31 CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE...

Страница 7: ...Flue Termination Fan Combustion System Ignition System Operation Temperature control Electronic thermostat High Low Off Flame picture select option Up Down buttons Temperature range Low 50 F 60 F 80 F...

Страница 8: ...uctions If you cannot reach your gas supplier call the fire dept C Use only your hand to push the gas control buttons Never use tools If the buttons will not activate by hand don t try and repair it c...

Страница 9: ...ss the ON OFF button OFF then ON again TURNING OFF Simply press the ON OFF button to switch off the unit The ON indicator will go out The convection fan will continue to operate for several minutes af...

Страница 10: ...hen the correct hour shows on the Digital Display Confirm that you have selected AM or PM as required a small indicator on the left hand side of the Digital Display indicates the AM PM setting Use the...

Страница 11: ...failure the system memory will retain the Timer programs and the clock will stop at the time the power goes off The clock will start again when the power comes back on but the time will be slow by th...

Страница 12: ...f the remote control The clip is removed by inserting a coin or similar into the recess in the back of the remote control and sliding downwards The battery must be of type CR 2032 and will only operat...

Страница 13: ...at room ventilation complies with local regulations 7 This heater must be mounted on a hearth not less than 2 thick and at least the width and depth of the heater 8 Installation location shall provide...

Страница 14: ...ns a zero clearance kit must be used Combustible installation This may require a sheet of non combustible material to be laid under the heater or a layer of cement to be poured on the hearth The firep...

Страница 15: ...be installed vertically only If installation prevents this then there must be at least 4 feet of vertical flue before any bends The flue must not fall below horizontal at any stage There must not be m...

Страница 16: ...remove the cover A hole is provided on the right hand side of the junction box for a suitable electrical gland to be attached and the electrical supply to pass through 6 There are two wires one black...

Страница 17: ...ewdriver and remove excess material Note The ember bed material must be placed after the logs are fitted If the logs are to be removed for any reason the ember bed material must be removed first and r...

Страница 18: ...3 It may take approximately 2 hours for the logs to achieve their full flame pattern and glow During the initial burning in period some smoke and smell may be experienced The heater should be run on t...

Страница 19: ...polishes to clean the casing while the fire is in operation Do not damage or distort any part of the heater Do not use wet cloth or spray cleaners on burners VENT MAINTENANCE The flue should be inspec...

Страница 20: ...not to damage the fiber seal on the perimeter of the glass 4 The glass may be cleaned with a damp sponge and soapy water If the seal is damaged it should be replaced Remove any soot deposit from the l...

Страница 21: ...21 WIRING DIAGRAM PCB LAYOUT Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing...

Страница 22: ...g up Small soot deposit Normal operation No action required Inadequate fluesystem Log misalignment Call service department agent Incorrect gas pressure Condensationon glass Normal operation Allow fire...

Страница 23: ...block Service call Power failure Service call Room temperature sensor faulty ERROR CODES ERROR CODE MESSAGE The Flame Fire ETR has the ability to check its own operation continuously If a fault occur...

Страница 24: ...24 EXPLODED DIAGRAMS...

Страница 25: ...25...

Страница 26: ...AME 23 2 7875 ELECTRODE 23 2 7520 THERMOCOUPLE 24 2 7876 ELECTRODE NUT S I T 25 2 7872 INJECTOR NG 51 NG 2 7873 INJECTOR LPG 31 LP 27 2 7900 ELECTRODE NUT ETR 28 2 7902 SPACER ELECTRODE PILOT 29 2 798...

Страница 27: ...N PANEL IBR ETR US 76 1 7601 1 FAN GUIDE TOP NAT IB35ETR 77 1 7613 FAN DIVIDING BRKT RH IB35ETR 78 2 7554 CLIP THERMISTER CP 90125 2 B 79 1 7989 REAR PANEL IBR USA 80 1 7197 REAR TOP PANEL IBR 81 1 71...

Страница 28: ...28 INSTALLATION NOTES...

Страница 29: ...29 INSTALLATION NOTES...

Страница 30: ...30 INSTALLATION NOTES...

Страница 31: ...__________________________ Date ___________________ INSTALLATION COMMISSIONING CHECKLIST INSTALLER DETAILS 1 Was a fireplace inspection carried out i e clearances combustibles etc 2 Was a manufactured...

Страница 32: ...Part Number 7919B zx...