NOTE:
If you have any other faults or problems, please refer to your
Installer
or local qualified service agency
WIRING DIAGRAM-LADDER
SYMPTOM
CAUSE
SOLUTION
No power present
Ensure power cord is plugged in and turned on
No gas present
Ensure gas supply is turned on
power cut
Re-ignite after power is restored
Air in gas pipe
Purge air (installer)
Ignition failure
Repeat lighting procedure.
Smell of gas
Leaking gas
Turn gas off at meter and call installer
Heater still warming up
Small soot deposit
Normal operation
No action required
Inadequate flue system
Log misalignment
Call service department/agent
Incorrect gas pressure
Condensation on glass
Normal operation
Allow fire to warm up
Streaky lines on glass
Normal operation
Remove and clean glass
Digital error message on
control panel
Electronic fault detected Refer
Error Messages page 23
Soot deposit forming on
glass or logs
Burner will not light
Fan not working
The fan is programmed to start after the heater has
been operating for 4 minutes.
Fan does not stop
Heater cooling down
The fan is programmed to continue running for 4
minutes after the burners have been extinguished