deactivate the LOCK press and hold the
button for 3 seconds until the indicator
goes off.

During normal operation the LOCK may be
activated and all controls, other than the
OFF switch, will be locked.  Deactivating
the LOCK releases the controls.

If the LOCK is activated while the unit is
turned OFF, then all functions will be locked
including the ON/OFF function.  If the unit
is turned OFF while the LOCK is activated,
it cannot be turned ON again until the
LOCK is deactivated.

• FLAME

To operate the FLAME function, press the
FLAME button.  This function will
automatically override the thermostat and
set the unit to a default Medium High heat
setting for full visual flame effect.

• AUTO OFF

AUTO OFF is activated by pressing the
button and the AUTO OFF indicator will
glow when on.

When the AUTO OFF function is on and
the room temperature reaches or exceeds
the pre-set temperature then the burners
will reduce to pilot only.

When the AUTO OFF is off then the burners
will reduce to the front (ember) burner and
pilots.

SETTING THE CLOCK

When the appliance is first plugged in or
after a power failure, the Digital Display will
show  

--:--

.

Press the SET TIMES button once, the
Clock indicator will flash.  Press and hold
the “

 “or “          “ button, the minutes will

begin to count up or down until they reach
00, the time will now change by one hour
increments.

Release the button when the correct hour
shows on the Digital Display. Confirm that

you have selected AM or PM as required,
a small indicator on the left hand side of
the Digital Display indicates the AM/PM
setting.

Use the buttons again to set the minutes.
Scroll up or down using the buttons until
the correct time is reached.

Press the TIMER SET button five times to
lock in the time. The CLOCK and TIMER
indicators will go out. A small indicator on
the digital display will flash to show that the
clock is operating.

TIMERS / PREHEAT

This heater has two programmable timers,
these allow you to set a start and finish
time.  The temperature is preset each time
the timers are activated.

There is also a preheat function that
measures the temperature of the room and
estimates the time it will take to bring the
room up to the preset temperature by the
programmed start time.

This means that the heater may start
heating an hour or more before the
programmed start time.

PROGRAMMING THE ON / OFF

TIMERS

Before programming the Timers you must
ensure that the clock has been set to the
correct time.

Press the SET TIMES button twice. The
digital display will show AM 6:00 and the
TIMER 1 - ON indicator will flash.

Set the desired start time the same way
as for setting the clock. Be aware that the
heater may start up much earlier than the
programmed start time due to the preheat
function, as explained earlier.

Press the SET TIMES button again, the
TIMER 1 - OFF indicator will flash.

Set the desired stop time the same way
as for setting the clock.

Press the SET TIMES button once to

Содержание IB35ETRLC

Страница 1: ...upplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance is only for use with the type of gas indicated on...

Страница 2: ...the Warranty For the name of the Authorized Distributor or Installer nearest you please contact your local HVAC dealer or gas service technician visit the Rinnai website www rinnai us call Rinnai at...

Страница 3: ...your safety read before operating heater 8 Control panel layout 9 Operation 9 Location 13 Venting 15 Gas connection 15 Log installation 16 Testing and commissioning 17 Maintenance instructions 18 Wiri...

Страница 4: ...er with forced convection and natural draft flue system Gas Control Electronic control valve Burners Ember bed flame and heat burner Warm Air Discharge Top front louvres Flue Natural draft Approved 4...

Страница 5: ...Refer to local gas authority for confirmation of the gas type if you are in doubt Included in the carton Customer operation information IMPORTANT Before using this product please read this manual care...

Страница 6: ...nst the appliance 30 DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITUREAND DRAPERIES 31 CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE...

Страница 7: ...Flue Termination Fan Combustion System Ignition System Operation Temperature control Electronic thermostat High Low Off Flame picture select option Up Down buttons Temperature range Low 50 F 60 F 80 F...

Страница 8: ...uctions If you cannot reach your gas supplier call the fire dept C Use only your hand to push the gas control buttons Never use tools If the buttons will not activate by hand don t try and repair it c...

Страница 9: ...ss the ON OFF button OFF then ON again TURNING OFF Simply press the ON OFF button to switch off the unit The ON indicator will go out The convection fan will continue to operate for several minutes af...

Страница 10: ...hen the correct hour shows on the Digital Display Confirm that you have selected AM or PM as required a small indicator on the left hand side of the Digital Display indicates the AM PM setting Use the...

Страница 11: ...failure the system memory will retain the Timer programs and the clock will stop at the time the power goes off The clock will start again when the power comes back on but the time will be slow by th...

Страница 12: ...f the remote control The clip is removed by inserting a coin or similar into the recess in the back of the remote control and sliding downwards The battery must be of type CR 2032 and will only operat...

Страница 13: ...at room ventilation complies with local regulations 7 This heater must be mounted on a hearth not less than 2 thick and at least the width and depth of the heater 8 Installation location shall provide...

Страница 14: ...ns a zero clearance kit must be used Combustible installation This may require a sheet of non combustible material to be laid under the heater or a layer of cement to be poured on the hearth The firep...

Страница 15: ...be installed vertically only If installation prevents this then there must be at least 4 feet of vertical flue before any bends The flue must not fall below horizontal at any stage There must not be m...

Страница 16: ...remove the cover A hole is provided on the right hand side of the junction box for a suitable electrical gland to be attached and the electrical supply to pass through 6 There are two wires one black...

Страница 17: ...ewdriver and remove excess material Note The ember bed material must be placed after the logs are fitted If the logs are to be removed for any reason the ember bed material must be removed first and r...

Страница 18: ...3 It may take approximately 2 hours for the logs to achieve their full flame pattern and glow During the initial burning in period some smoke and smell may be experienced The heater should be run on t...

Страница 19: ...polishes to clean the casing while the fire is in operation Do not damage or distort any part of the heater Do not use wet cloth or spray cleaners on burners VENT MAINTENANCE The flue should be inspec...

Страница 20: ...not to damage the fiber seal on the perimeter of the glass 4 The glass may be cleaned with a damp sponge and soapy water If the seal is damaged it should be replaced Remove any soot deposit from the l...

Страница 21: ...21 WIRING DIAGRAM PCB LAYOUT Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing...

Страница 22: ...g up Small soot deposit Normal operation No action required Inadequate fluesystem Log misalignment Call service department agent Incorrect gas pressure Condensationon glass Normal operation Allow fire...

Страница 23: ...block Service call Power failure Service call Room temperature sensor faulty ERROR CODES ERROR CODE MESSAGE The Flame Fire ETR has the ability to check its own operation continuously If a fault occur...

Страница 24: ...24 EXPLODED DIAGRAMS...

Страница 25: ...25...

Страница 26: ...AME 23 2 7875 ELECTRODE 23 2 7520 THERMOCOUPLE 24 2 7876 ELECTRODE NUT S I T 25 2 7872 INJECTOR NG 51 NG 2 7873 INJECTOR LPG 31 LP 27 2 7900 ELECTRODE NUT ETR 28 2 7902 SPACER ELECTRODE PILOT 29 2 798...

Страница 27: ...N PANEL IBR ETR US 76 1 7601 1 FAN GUIDE TOP NAT IB35ETR 77 1 7613 FAN DIVIDING BRKT RH IB35ETR 78 2 7554 CLIP THERMISTER CP 90125 2 B 79 1 7989 REAR PANEL IBR USA 80 1 7197 REAR TOP PANEL IBR 81 1 71...

Страница 28: ...28 INSTALLATION NOTES...

Страница 29: ...29 INSTALLATION NOTES...

Страница 30: ...30 INSTALLATION NOTES...

Страница 31: ...__________________________ Date ___________________ INSTALLATION COMMISSIONING CHECKLIST INSTALLER DETAILS 1 Was a fireplace inspection carried out i e clearances combustibles etc 2 Was a manufactured...

Страница 32: ...Part Number 7919B zx...

Отзывы: