INSTALLATION - SOLAR COLLECTORS
Rinnai 18
DD FP Solar Pre Heat System OIM
INSTALLATION ON A FLAT ROOF FRAME
WARNING
Not suitable for use in cyclone areas
When installing on a roof over 10 metres in height, the frame must be fastened to the roof in
conjunction with the “High Rise Roof Mounting Frame Installation Instruction” (15401103) and
the longer clamping brackets supplied in DDHRKIT2 and DDHRKIT3
MUST
be used.
•
Assemble the frame as described in “Installation Manual - Roof Frames for Use with Rinnai Solar Hot Water
Systems”
•
Fasten the mounting rails to the frame using the bolts, washers and lock nuts provided in the frame kit.
•
Join the collectors using the compression unions and place the collectors onto the rail. Position second rail
above the collector and fasten to frame using bolts, washers and lock nuts.
•
Push down on the clamping brackets to allow the locking teeth to hold the collector in position. Tighten the
nut and bolt to securely fasten the clamping bracket in place.