Ember Installation Guide: 12890-F 06-21
|
17
Flue cowl needs to a 500 mm clearance from the
nearest ridge line of the roof. In this instance the
flue pipe has been painted to match the roof.
Self-supporting coaxial flue; inner
Ø 100 mm, outer Ø 170 mm. Requires
10 mm clearance to a combustible
surface. Flue pipes twist and lock into
place.
Colinear to coaxial adaptor supported
and secured in place. Flexi flues clamped
and screwed to the connections.
Base of enclosure MUST BE level
and allow free movement of the
appliance for maintenance and
servicing.
Zero clearance frame fitted,
refer next page
600 mm maximum
Maximum vertical flue length is
10 m. If adding 2 x 45 ° bends
(maximum number of bends),
then the flue length reduces by
2 m, refer p. 34.