18
|
Arriva/Evolve flue installation guide: 10726-I 09-21
Down-and-out flueing
The down-and-out flue option allows for the adaption flue kit to face downwards
and for the flue to run vertically through a hole in the floor, and then horizontally
to a suitable location outside. When considering the location of the heater
due care must be taken to ensure that the flue path under the floor is free of
obstructions such as studs, noggins, joists, braces, wiring etc.
1
2
3
4
4
4
5
Interio
r wall
Interio
r wall
Wall plate
Stand off clip
Interio
r wall
Floor penetration
1. Flue slide stopper (provided with the
ASPKIT03/EVOKIT03).
2. Air hose from unit.
3. Condensate trap component—acts
as a transition piece (arrow points
down, and it should be capped or
sealed).
4. Wall straps (provided with each flue
kit).
5. 2° fall to wall terminal to drain
condensate.
Flue length
In this example the flue could be up to
6.5 m long and contain one 90 ° bend.
Important
Flue terminal must terminate horizontally
300 mm above ground level. It must not
terminate under the building.
Down and out configuration overview using the Arriva as an example
Down and out configuration overview using the Arriva as an example