Installation and operating instructions for
Rail Clamp DR 085/088 FHM
spring activated
– hydraulically released
E 09.797e
Issue: 14.09.2022
Version: 2
Drawn: BAHS
Checked: OHLM
Pages: 39
Page: 26
3.4 Hand pump operation oft he rail clamp
Use the hand pump (if supplied) to release open the rail clamp manually (without electric
current).
Refer to the corresponding hydraulic power unit for more information.
Information!
Refer to the corresponding hydraulic power unit for more information.
4
PERIODIC MAINTENANCE
Attention!
The rail clamps DR 085/088 FHM with diamond pads are intented for
purely static uses. Any dynamic braking requires a replacement of the
pads.
The rail should be free of lubricants and oils so that the coefficient of
friction does not drop. If this instruction is not observed, braking force
may be lost.
The air gap must be adjusted after replacing the friction block.
Attention!
When changing the friction block, replace the friction block according
to chapter 5. If this instruction is not observed, braking force may be
lost.
Only original RINGSPANN friction pads may be used.