![RINGSPANN DR 085 FHM-100 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/ringspann/dr-085-fhm-100/dr-085-fhm-100_installation-and-operating-instructions-manual_1462317016.webp)
Installation and operating instructions for
Rail Clamp DR 085/088 FHM
spring activated
– hydraulically released
E 09.797e
Issue: 14.09.2022
Version: 2
Drawn: BAHS
Checked: OHLM
Pages: 39
Page: 16
Fig. 2.12
For rail clamps DR 085/088 FHM with HCO2R built-in hydraulic power unit:
Refer to the hydraulic power unit HCO2R manual for more information.
Important!
Power units are normally supplied with oil and are ready for operation.
However, check that the level is correct and that transport has not
caused any leakage.
Transport protection remove before usage: Remove the plug screwed
onto the filler hole and screw the breather plug supplied.
bleed screw
Connection
G1/4“ or G3/8“