RIGOL
User’s Guide for DSA1000 Series
1-21
User interface legends (Continued)
NO.
Name
Description
5
Input impedance
Show “75Ω” if the current input impedance is 75Ω.
6
Printer status
: Alternate display, denotes the printer now is
connecting.
: Successful connection, print finish or idle.
: Alternate display, denotes printing.
: Denotes print has been paused.
7
Print process
Show current print copy and total print copies.
8
Power status
AC supply:
Battery supply (China only): show electric quantity left
9
USB storage
device
Show if USB storage device is inserted; the mark
indicates successfully installed.
10
Operation status
Local or Rmt (Remote).
11
Menu title
Function of current menu belongs to.
12
Menu item
Menu item of current function.
13
Reference level
Reference level.
14
Active area
Current parameter and value.
15
Attenuator
settings
Sets the Attenuator.
16
Display line
Reading reference and threshold condition for peak
value.
17
Trigger level
Sets the trigger level in video trigger.
18
Average times
Average times of trace.
19
Cursor X
Current value of Cursor X. Note that X indicates
different physical quantity in different functions.
20
Cursor Y
Current value of Cursor Y. Note that Y indicates
different physical quantity in different functions.
21
Invalid data
Current measured data is invalid as a full sweep didn’t
complete after the system parameters have been
modified.
22
Menu pages
Show total number of pages and current page
number.
23
Sweep position
Current sweep position.
24
Sweep time
Sweep time.
Содержание DSA1030
Страница 1: ...RIGOL User s Guide DSA1000 Series Spectrum Analyzer Sept 2014 RIGOL Technologies Inc...
Страница 2: ......
Страница 22: ......
Страница 179: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 3 Figure 3 1 Measuring a Sine signal...
Страница 181: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 5 Figure 3 2 Use the frequency counter to measure...
Страница 186: ...RIGOL Measurement Examples 3 10 User s Guide for DSA1000 Series Figure 3 4 Phase noise measurement...
Страница 188: ...RIGOL Measurement Examples 3 12 User s Guide for DSA1000 Series Figure 3 5 N dB bandwidth measurement result...
Страница 190: ...RIGOL Measurement Examples 3 14 User s Guide for DSA1000 Series Figure 3 6 Time domain power measurement...
Страница 192: ...RIGOL Measurement Examples 3 16 User s Guide for DSA1000 Series Figure 3 7 Adjacent channel power measurement result...
Страница 194: ...RIGOL Measurement Examples 3 18 User s Guide for DSA1000 Series Figure 3 8 Channel power measurement result...
Страница 196: ...RIGOL Measurement Examples 3 20 User s Guide for DSA1000 Series Figure 3 9 Occupied bandwidth measurement result...
Страница 198: ...RIGOL Measurement Examples 3 22 User s Guide for DSA1000 Series Figure 3 10 Emission bandwidth measurement result...
Страница 200: ...RIGOL Measurement Examples 3 24 User s Guide for DSA1000 Series Figure 3 11 C N Ratio measurement result...
Страница 204: ...RIGOL Measurement Examples 3 28 User s Guide for DSA1000 Series Figure 3 13 Harmonic Distortion measurement result...
Страница 211: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 35 Figure 3 17 Amplitude correction...
Страница 213: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 37 Figure 3 18 The frequency response of a filter...
Страница 214: ......