RIGOL
5-4
User’s Guide for DSA1000 Series
device condition.
Message number: -299 to -200.
(3)
Device Specific Error: indicates a device specific error is generated when the
commands cannot be correctly executed due to current settings of the
hardware and software of the device.
Message number: -399 to -300 (defined in SCPI standard) and 300 to 1000.
(4)
Query Error: indicates a query error is generated when the output queue
controller (see IEEE488.2,6.5.7) fails to follow the Message Exchange
Control Protocol under any of the conditions below: ( see IEEE488.2,6.1.10)
When trying to read the output queue, the queue has no data or is being
suspended.
Data in the output queue has been lost.
Message number: -499 to -400.
3.
Status Message: to warn you that the analyzer is now in a certain condition and
should be paid attention to. The messages are always marked with an icon
and displayed on the screen until the Esc key has been pressed or the *CLS
command is used. The messages are stored in corresponding status register, and
can be queried by sending :Status: or :SYSTEM:ERROR[:NEXT]?.
Message number: 200 to 299.
Содержание DSA1030
Страница 1: ...RIGOL User s Guide DSA1000 Series Spectrum Analyzer Sept 2014 RIGOL Technologies Inc...
Страница 2: ......
Страница 22: ......
Страница 179: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 3 Figure 3 1 Measuring a Sine signal...
Страница 181: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 5 Figure 3 2 Use the frequency counter to measure...
Страница 186: ...RIGOL Measurement Examples 3 10 User s Guide for DSA1000 Series Figure 3 4 Phase noise measurement...
Страница 188: ...RIGOL Measurement Examples 3 12 User s Guide for DSA1000 Series Figure 3 5 N dB bandwidth measurement result...
Страница 190: ...RIGOL Measurement Examples 3 14 User s Guide for DSA1000 Series Figure 3 6 Time domain power measurement...
Страница 192: ...RIGOL Measurement Examples 3 16 User s Guide for DSA1000 Series Figure 3 7 Adjacent channel power measurement result...
Страница 194: ...RIGOL Measurement Examples 3 18 User s Guide for DSA1000 Series Figure 3 8 Channel power measurement result...
Страница 196: ...RIGOL Measurement Examples 3 20 User s Guide for DSA1000 Series Figure 3 9 Occupied bandwidth measurement result...
Страница 198: ...RIGOL Measurement Examples 3 22 User s Guide for DSA1000 Series Figure 3 10 Emission bandwidth measurement result...
Страница 200: ...RIGOL Measurement Examples 3 24 User s Guide for DSA1000 Series Figure 3 11 C N Ratio measurement result...
Страница 204: ...RIGOL Measurement Examples 3 28 User s Guide for DSA1000 Series Figure 3 13 Harmonic Distortion measurement result...
Страница 211: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 35 Figure 3 17 Amplitude correction...
Страница 213: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 37 Figure 3 18 The frequency response of a filter...
Страница 214: ......