User’s Guide for DSA1000 Series
5-11
5.2.2.2
Execution Error
Number Error Description
-200
Execution error.
This is the generic syntax error for devices that cannot detect more
specific errors. This code indicates only that an Execution Error as
defined in IEEE 488.2, 11.5.1.1.5 has occurred.
-201
Invalid while in local.
Indicates that a command is not executable while the device is in local
due to a hard local control (see IEEE 488.2, 5.6.1.5);The system would
be changed to remote mode by selecting the right communication I/O.
-203
Command protected.
Indicates that a legal password-protected program command or query
could not be executed because the command was disabled.
-220
Parameter error.
Indicates that a program data element related error occurred. This
error message should be used when the device cannot detect the more
specific errors described for errors -221 through -229.
-221
Settings conflict.
Indicates that a legal program data element was parsed but could not
be executed due to the current device state (see IEEE 488.2, 6.4.5.3
and 11.5.1.1.5.)
-222
Data out of range.
Indicates that a legal program data element was parsed but could not
be executed because the interpreted value was outside the legal range
as defined by the device (see IEEE 488.2, 11.5.1.1.5.)
-223
Too much data.
Indicates that a legal program data element of block, expression, or
string type was received that contained more data than the device
could handle due to memory or related device-specific requirements.
-224
Illegal parameter value.
Used where exact value, from a list of possible, was expected.
-225
Out of memory.
The device has insufficient memory to perform the requested
operation.
-233
Invalid version.
Indicates that a legal program data element was parsed but could not
be executed because the version of the data is incorrect for the device.
Содержание DSA1030
Страница 1: ...RIGOL User s Guide DSA1000 Series Spectrum Analyzer Sept 2014 RIGOL Technologies Inc...
Страница 2: ......
Страница 22: ......
Страница 179: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 3 Figure 3 1 Measuring a Sine signal...
Страница 181: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 5 Figure 3 2 Use the frequency counter to measure...
Страница 186: ...RIGOL Measurement Examples 3 10 User s Guide for DSA1000 Series Figure 3 4 Phase noise measurement...
Страница 188: ...RIGOL Measurement Examples 3 12 User s Guide for DSA1000 Series Figure 3 5 N dB bandwidth measurement result...
Страница 190: ...RIGOL Measurement Examples 3 14 User s Guide for DSA1000 Series Figure 3 6 Time domain power measurement...
Страница 192: ...RIGOL Measurement Examples 3 16 User s Guide for DSA1000 Series Figure 3 7 Adjacent channel power measurement result...
Страница 194: ...RIGOL Measurement Examples 3 18 User s Guide for DSA1000 Series Figure 3 8 Channel power measurement result...
Страница 196: ...RIGOL Measurement Examples 3 20 User s Guide for DSA1000 Series Figure 3 9 Occupied bandwidth measurement result...
Страница 198: ...RIGOL Measurement Examples 3 22 User s Guide for DSA1000 Series Figure 3 10 Emission bandwidth measurement result...
Страница 200: ...RIGOL Measurement Examples 3 24 User s Guide for DSA1000 Series Figure 3 11 C N Ratio measurement result...
Страница 204: ...RIGOL Measurement Examples 3 28 User s Guide for DSA1000 Series Figure 3 13 Harmonic Distortion measurement result...
Страница 211: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 35 Figure 3 17 Amplitude correction...
Страница 213: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 37 Figure 3 18 The frequency response of a filter...
Страница 214: ......