Enters the Options management interface and uses the direction key to select an
option and input correct license so as to install the option. Each option has a unique
license and can only be used in the analyzer itself. For more information about the
options, refer to “Appendix A: ”.
1.
Acquire the license
1)
Order the corresponding option to acquire the option key.
2)
Log in
RIGOL
website (www.rigol.com). Click “Customer Center” and select
“License Generate” to enter the software license generation interface.
3)
Input the option key, instrument serial number (press System
Information
System Info to acquire the instrument serial number) and
identifying code; click “Generate” to get the corresponding option license.
2.
Install the option
1)
License
Press License to open the input box and input the option license using the
numeric keys and knob at the front panel. For example,
646K204P69N0P0395P899156121M2M9OKO4L056728N399PO. After
entering all the characters, press Save. At this point, the Active bar is in
inactive (“N”) state.
2)
Active
Press Active to activate the input option license. At this point, the Active bar
is in active (“Y”) state. The option is successfully installed.
Tip:
You can also install the option by operating the spectrum analyzer remotely.
1.
Build the communication between the spectrum analyzer and PC. You can
use the USB, LAN or GPIB (option) interface. For the connecting methods,
refer to “Remote Control”.
2.
Send the :SYSTem:LKEY <option>,<license key> command. For
example, :SYSTem:LKEY
0002,646K204P69N0P0395P899156121M2M9OKO4L056728N399PO. The
spectrum analyzer recognizes the license received and matches it with the
corresponding option. At this point, the corresponding option is installed and
is in active state (the Active bar shows “Y”).
Содержание DSA1030
Страница 1: ...RIGOL User s Guide DSA1000 Series Spectrum Analyzer Sept 2014 RIGOL Technologies Inc...
Страница 2: ......
Страница 22: ......
Страница 179: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 3 Figure 3 1 Measuring a Sine signal...
Страница 181: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 5 Figure 3 2 Use the frequency counter to measure...
Страница 186: ...RIGOL Measurement Examples 3 10 User s Guide for DSA1000 Series Figure 3 4 Phase noise measurement...
Страница 188: ...RIGOL Measurement Examples 3 12 User s Guide for DSA1000 Series Figure 3 5 N dB bandwidth measurement result...
Страница 190: ...RIGOL Measurement Examples 3 14 User s Guide for DSA1000 Series Figure 3 6 Time domain power measurement...
Страница 192: ...RIGOL Measurement Examples 3 16 User s Guide for DSA1000 Series Figure 3 7 Adjacent channel power measurement result...
Страница 194: ...RIGOL Measurement Examples 3 18 User s Guide for DSA1000 Series Figure 3 8 Channel power measurement result...
Страница 196: ...RIGOL Measurement Examples 3 20 User s Guide for DSA1000 Series Figure 3 9 Occupied bandwidth measurement result...
Страница 198: ...RIGOL Measurement Examples 3 22 User s Guide for DSA1000 Series Figure 3 10 Emission bandwidth measurement result...
Страница 200: ...RIGOL Measurement Examples 3 24 User s Guide for DSA1000 Series Figure 3 11 C N Ratio measurement result...
Страница 204: ...RIGOL Measurement Examples 3 28 User s Guide for DSA1000 Series Figure 3 13 Harmonic Distortion measurement result...
Страница 211: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 35 Figure 3 17 Amplitude correction...
Страница 213: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 37 Figure 3 18 The frequency response of a filter...
Страница 214: ......