8. Error codes
E01: Binding unit end micro switch
Electric check:
-
First of all, check the position of the binding unit, that in which position/phase
occurred the problem/error.
-
In case the error appeared during closing but it did not finished the closing
procedure, check the fuse of the motor and the short circuit of the motor.
-
In case the error appeared after it is closed, then check the micro switch
(binding unit close switch)
-
In case the error appeared after it is closed but it did not open, and then check
the fuse of the motor and the short circuit of the motor.
-
In case the error appeared after it is closed and it is opened, and then check
the micro switch (binding unit open switch)
Mechanical check:
-
Check the position of the spring holder „forks” upside or downside.
E02: Carriage clamp opening micro switch
Electric check:
-
Check the fuse of the clamp open/close motor.
-
Clamp close sensor’s micro switch is jammed or out of order.
Mechanical check:
-
Check if there is any mechanical blockage.
E03: Carriage clamp closing micro switch
Electric check:
-
Check the fuse of the clamp open/close motor.
-
Clamp close sensor’s micro switch is out of order.
-
Clamp open end micro switch or it’s diode is out of order.
Mechanical check:
-
Check if there is any mechanical blockage.