RigMaster LG200 Installation Manual
Section 10
August 2010 RigMaster Power International Ltd LG200 Service Manual
NOTE
Prior to mounting the fuse assembly, ensure that the 18 inch battery cable will
re ac h th e p o si ti v e ba tt er y ter m in a l a nd t he f u se a s s em b ly .
3. Cut back any excess cable that connects the LG200 to the fuse assembly
and secure the 5/16” eye terminal. The use of shrink tube and dielectric
grease on all points of connection is highly recommended.
10:3:0
Installing the Battery Cables to the Vehicles Battery Bank
NOTE
Before connecting the battery cables to the vehicles batteries make sure all
connections are made at the power module and cabin controller first.
Route the battery cables to the battery compartment and cut the excess cable.
Fit the shrink tube to the cables and connect the 3/8 terminals.
Connection 1:
Positive cable to the vehicles batteries (Figure 11-4)
Ensure that the positive battery terminal is clean and connect the red battery
cable.
Connection 2:
Negative cable to the truck batteries (Figure 11-4)
Ensure that the negative battery terminal is clean and connect the black battery
cable.
Figure 10-5
4. Connect the fuse assembly to the
positive battery terminal with the 18
inch positive battery cable prior to
connecting the LG200’s negative
terminal.
Содержание MTS-T4-LG200
Страница 1: ...Installation Manual MTS T4 LG200 ...
Страница 59: ...RigMaster LG200 Installation Manual Notes August 2010 RigMaster Power International Ltd LG200 Service Manual ...
Страница 60: ...RigMaster LG200 Installation Manual Notes August 2010 RigMaster Power International Ltd LG200 Service Manual ...
Страница 61: ...RigMaster LG200 Installation Manual Notes August 2010 RigMaster Power International Ltd LG200 Service Manual ...