RigMaster LG200 Installation Manual
Section 9
August 2010 RigMaster Power International Ltd LG200 Service Manual
9:3:0
Evaporator Temperature Switch Wiring Connections
9:4:0
GROUND WIRES
There are 2 ground wires that need to be
attached under one of the blots on the
power module coming from the unit.
9:5:0
Connecting the Cabin Controller
J3 Connection
Green Wire – 12V from
Power Module
Blue Wire – 12V to Binary
Pressure Switch
Connect the communication cable to the cabin controller first (see section 4) and
then route it to the power module. Coil any excess
cable and secure it with wire ties. Connect the 8
pin communication cable to the J3 terminal.
9:6:0
DPF Backpressure Monitor Wire
The LG200 is designed to accommodate a Diesel
Particulate Filter as an optional upgrade. An
exhaust backpressure monitor will be supplied with
the kit. The back pressure monitor integrates with
the silver power module bearing the part number
RP50-250. The wiring harness has a blue wire with a white stripe that is to be
connected to the module only when the DPF kit has been installed. Do not connect
this wire unless there is a DPF kit present of the APU. Instead tie the wire off to
prevent damage and cover the tip with electrical tape.
WIRING THE EVAPORATOR
THERMOSTAT
Figure 9-2
Содержание MTS-T4-LG200
Страница 1: ...Installation Manual MTS T4 LG200 ...
Страница 59: ...RigMaster LG200 Installation Manual Notes August 2010 RigMaster Power International Ltd LG200 Service Manual ...
Страница 60: ...RigMaster LG200 Installation Manual Notes August 2010 RigMaster Power International Ltd LG200 Service Manual ...
Страница 61: ...RigMaster LG200 Installation Manual Notes August 2010 RigMaster Power International Ltd LG200 Service Manual ...