10
Laser Triangulation Sensors. RF602 Series
RF602 [Revision 1.2.0] 28.01.2019
In the
"Reset of the Ethernet packets counter"
mode, connection AL input to the
ground potential resets the counter (Fig. 3.3)*.
*Note.
A low level of the AL line is holding for 100 s or more, and a high level of
the AL line is holding for 100 s.
Out of the range indication
Mutual synchronization
Hardware zero-set/
Hardware laser ON/OFF
Figure 3.1
Figure 3.2
Figure 3.3
10.6. Time lock of the result
If the sensor does not find the object or if the authentic result cannot be received, a
zero value is transferred. The given parameter sets time during which the last authentic
result is transferred.
10.7. Method of results averaging
This parameter defines one of the two methods of averaging of measurement
results implemented directly in the sensor:
·
Averaging over a number of results
·
Time averaging
When
averaging over a number of results
is selected, sliding average is
calculated.
When
time averaging
is selected, the results obtained are averaged over the time
interval chosen.
10.8. Number of averaged values/time of averaging
This parameter specifies the number of source results to be averaged for deriving
the output value or time of the averaging .
The use of averaging makes it possible to reduce the output noise and increase the
sensor resolution.
Averaging over a number of results does not affect the data update in the sensor
output buffer.
In case of time averaging, data in the output buffer are updated at a rate equal to the
averaging period.
Note
. The maximum value is 127.