26
Laser Triangulation Sensors. RF602 Series
RF602 [Revision 1.2.0] 28.01.2019
13.7. Display, gathering and scanning of data
Measurement result is displayed in digital form and in the form of oscillogram and is
stored in the PC memory.
·
The number of points displayed along the X coordinate can be set in the
Number
of points in buffer
window.
·
Scaling method along the Y coordinate can be set by the
Auto scaling
function.
·
Turn-on/turn-off of the scaling grid is effected by using the
Grid
function.
·
The number of displayed digits after decimal point can be set in the
Set digits
after point
window.
·
To save received data to a file, select (tick)
Write data file
.
Note
: the number of points displayed on the graph depends on PC speed and
becomes smaller in proportion to the data transmission rate. After the stream is stopped by
using the
Stop Stream
button, the graph will display all data received.
·
To work with the image, press the right mouse key on the graph to call the
corresponding menu:
·
To move the image, just press the mouse wheel.
·
To zoom, rotate the mouse wheel.
·
To save data to a file, press the
Export
button. The program will offer saving of
data in two possible formats: internal and Excel.
·
To scan or look at previously saved data, press the
Import
button and select the
required file.