background image

 

Wheel diameter measuring gauge, IDK-BT 

 

 

IDK-BT [Revision 2.2]  4

th

 September  2017 

1. 

Safety precautions and measurement conditions 

  The metering accuracy depends greatly on the wheel surface quality. There-

fore it is necessary to carry out the check and presorting of the wheel surface 
roughness and flaws before measuring the diameter. 

  Prior  to  place  the  gauge  onto  the  wheel  there  is  a  need  to  clean  the  wheel 

parts that contact with gauge ball bearings, side supports and measuring tip, 
of the mud. 

  At arranging the gauge, do not allow hitting its supports on the wheel and any 

measuring tip side hitting  

  At  arranging  the  gauge,  do  not  apply  strong  forcing  in  the  direction  of  the 

measuring tip movement. It can result in the gauge sag, that will bring about 
the uncertain metering result 

  It is necessary to inspect the gauge supports periodically and to cleanse them 

  To  save  the  battery  power  the  display  extinguishes  if  there  were  no  buttons 

pressings for 60 seconds, at that only blinking dot is shown. Pressing any but-
ton just turns on the display and does not act in any other way in this case. 

2. 

Electromagnetic compatibility 

The gauge has been developed for use in industry and meets the requirements 

of the following standards: 

  EN 55022:2006 Information Technology Equipment. Radio disturbance char-

acteristics. Limits and methods of measurement.  

  EN 61000-6-2:2005 Electromagnetic compatibility (EMC). Generic standards. 

Immunity for industrial environments. 

  EN 61326-1:2006 Electrical Equipment for Measurement, Control, and Labor-

atory Use. EMC Requirements. General requirements. 

3. 

General information 

Electronic gauge is designed for measuring wheel rolling circle diameter (amount 

of  wear)  of  railway,  metro  and  tram  in  the  course  of  checkup,  examination,  repair  and 
formation of wheel sets. Measurements are made directly on rolling stock without wheel 
set roll-out.  

4. 

Basic data and performance characteristics 

Name of parameter 

Value 

Measurement range, mm 

4

00…1400 or on request 

Measurement error, mm 

±0.2 

Indication discreteness 

0.1mm, 0.01mm * or 0.01 inch ** 

Position of measurement, S, mm 

On request 

Distance between axes of ball bearings (base), mm  
and measurement range, mm 

122±0.5 (400…750 mm) or  
200±0.5 (400…950 mm) or  

250±0.5 (600…1400 mm) or  

300±0.5 (720…1400 mm) 

Display 

build-in, LED 

Operating temperature, 

0

-

5…+55 

Power supply 

– built-in rechargeable battery 

two AAA 1,2V 

The number of measurements that can be taken before battery  recharge is 
not less than 

1000 

Weigh, kg 

0,5 

Содержание IDK-BT Series

Страница 1: ...ertified according to ISO 9001 2008 WHEEL DIAMETER MEASURING GAUGE IDK BT Series 22 Logoisky tract Minsk 220090 Republic of Belarus tel fax 375 17 357 36 57 info riftek com www riftek com User s manua...

Страница 2: ...e and PDA activation 13 12 2 1 Gauge turn on 13 12 2 2 PDA turn on 13 12 3 On line measurement 14 12 4 Measurements with database maintenance 15 12 5 Browsing the database 16 12 6 Saving database on f...

Страница 3: ...gauge has been developed for use in industry and meets the requirements of the following standards EN 55022 2006 Information Technology Equipment Radio disturbance char acteristics Limits and methods...

Страница 4: ...and together with RF303 PDA or PC with measurements saving in database Example IDK 70 250 850 1260 BT Position of measurement 70 mm base of the gauge 250 mm bottom of measuring range 850 mm up of meas...

Страница 5: ...e two side magnet supports to base the gauge to the wheel edge and a measuring tip There are a digital numeric display and control buttons on the front panel of the gauge Charge connector for charging...

Страница 6: ...th September 2017 6 Figure 2 Fig 2 indicates 1 Turn on button 2 Charging indication red blue LED 3 Connector to PC USB port or charging device 4 Flash memory card connector 5 Stylus 6 Bluetooth antenn...

Страница 7: ...o turn on the power The display shows ErrP message if the accumulator battery voltage became lower then the control level In this case the short term work is possible after pressing any key 9 2 Single...

Страница 8: ...a new position and repeat the measuring The total quantity of measurements averaged in this way can run up to 9999 Press Red button to reset averaging result at switching to another wheel For viewing...

Страница 9: ...press Blue button and keep it pressed for more than three seconds display will show bt On or bt OF press Blue button again Display will show Up by the pressing of Green button turn over the image the...

Страница 10: ...the changed parameters press Red button the display shows SAUE message press the Green button to confirm saving and Red to cancel saving of the changed parameters At brightness choosing one should tak...

Страница 11: ...get into this mode it is necessary to press Green button see p 11 3 For transition to next mode it is necessary to press Blue button Display shows CLbr b message the mode of device base calibration To...

Страница 12: ...made by pressing the Blue button while changing of values is made by pressing the Green button When editing is finished press the Red button and confirm or cancel saving of the parame ter by pressing...

Страница 13: ...pair number etc 12 2 Gauge and PDA activation 12 2 1 Gauge turn on Press Red button to turn on the power The display shows ErrP message if the accumulator battery voltage became lower then the control...

Страница 14: ...eel make sure the ball supports are tight against the roll surface and side sup ports are adjacent to the edge of the wheel press Green button Note hereinafter the button marked by green or red color...

Страница 15: ...to a new position and repeat the measuring The total quan tity of measurements averaged in this way can run up to 9999 Press Red button to reset averaging result at switching to another wheel 12 4 Me...

Страница 16: ...ain measurement Measure the wheel offered by the program highlighted in green color as it is shown in par 12 3 after the measurement the PDA will show the value of diameter When a diameter falls out o...

Страница 17: ...rsal connector insert flash card to the respective cable connector select Device Save to USB flash in the main program window if saving is successful the screen will show Data saved on USB Flash remov...

Страница 18: ...View on the PDA screen write data and time press Save 13 3 Tolerances settings The program automatically controls measured geometric parameters for going out beyond the tolerances set It is possible f...

Страница 19: ...ogram makes it possible to simultaneously create and store several database files connected with a concrete date of taking measurements To select a database file choose Service DB files in the main wi...

Страница 20: ...chemes View on the screen by activating lines containing the scheme file name it is possible to look at available wheel processing schemes Arrows in the figure show direction of processing of wheel se...

Страница 21: ...d changing of language and terminology It is possible for the user to change the program language form his own lan guage support files as well as change edit the terminology used To choose language in...

Страница 22: ...e folder to change and edit terminology it is necessary to edit the corresponding language file by using any text processor save the edited lng file in the Language folder 13 8 PDA software version vi...

Страница 23: ...n with the gauge If the connection is successful the Measurement button in the main program window becomes active You can begin to measure diameter measurement reset averaging result on the screen 14...

Страница 24: ...ram can be downloaded from www riftek com resouce files ikp5 zip User s manual from this address www riftek com resource download ikpm_riftek_eng pdf 16 Charging of built in accumulator battery To cha...

Страница 25: ...Wheel diameter measuring gauge IDK BT IDK BT Revision 2 2 4th September 2017 25 when drivers are installed the corresponding message and Bluetooth icon will appear in the screen activate IDK...

Страница 26: ...will start working tick the Device is installed and ready for connection select Next for search when the search is competed the wizard will show the devices found select the required device IDK press...

Страница 27: ...th September 2017 27 press Next and continue installation process when required drivers are installed the Bluetooth device will give a message with COM port outgoing which should be opened for connect...

Страница 28: ...ng China Tel 86 10 6765 0516 Fax 86 10 6765 6966 Mobile 86 137 1755 1423 dh0526 163 com www baoft cn CHINA JRKtech Co Ltd 1F Building 9 100 Xianlie Rd Guangzhou China Tel 86 755 85267190 86 1598936248...

Страница 29: ...3686 0831 f_kuribayashi tokyoinst co jp www tokyoinst co jp LATVIA ESTONIA SIA SOLARTEX RAILWAY INSTRUMENTS ONLY Duntes 15a 5th floor office B7 Riga Latvia Tel 371 67 130 787 solartex inbox lv MALAYS...

Страница 30: ...ronix se www latronix se TAIWAN Nano Trend Technology Co Ltd No 365 6 Zhongshan Rd Sanxia Dist New Taipei City 23741 Taiwan R O C Tel 886 2 8671 9560 Fax 886 2 8671 0084 nt nano trend com www nano tre...

Страница 31: ...the railhead act ing face visualization of the combined graphical images of actual and new cross section railhead profiles on the dis play of system unit Wheel diameter measuring gauge IDK Series Ele...

Страница 32: ...ce full profile scanning and analyze of the disc brakes acting face visualization of the combined graphical images of actual and new disc brakes profiles on the display of sys tem unit Automatic real...